Starting up and operation
Hard disk drive indicators
1
Figure 19: Indicators on the 3.5 inch and 2.5 inch HDD modules
1 LED
HDD BUSY
green
– Lights up: HDD in active phase
– Does not light: HDD inactive (drive inactive)
2 LED
HDD FAULT (orange)
orange
(in conjunction with a RAID controller)
– Does not light: no HDD error
– Lights up: HDD Faulty or Rebuild Stopped (drive
defective/needs replacing, a rebuild process was stopped or the
HDD module is not correctly inserted)
– Slow flashing: HDD Rebuild (the data is being restored after
changing a drive)
– Fast flashing: HDD Identify
– Four fast blinks/pause: HDD Predicted Fault
– Two fast flashes/pause: HDD Hot Spare (Hot spare drive active.
The corresponding drive has failed).
RX300 S5
2
Operating manual
Controls and indicators
1
2
65