For Your Safety - Omega Altise AVAP10A Instruction Manual

10 litre evaporative cooler
Table of Contents

Advertisement

4. Unscrew rear fixing back cover screws and release the back cover.
5. Disconnect the electric motor connection and remove the complete filter
assembly by pulling out from the top and then lifting the filter assembly - up and
out.
6. The air filter is connected into the back cover via two clips at the top. Release by
pressing the two clips down and give it a little push. Be careful not to damage
the filter.
CAUTION: Do not immerse or allow the motor or electric cables to come in contact with any liquid.
Do not immerse the Photocatalysis filter in water or any other liquid.
This filter should not be allowed to become wet. It should be placed in a
sunny position to reactivate it.
7. The water curtain is supported by two rollers, which can be removed for
cleaning with mild soap. It is recommended to be cleaned once every 6 months.
8. Wipe out and dry the water reservoir. Replace the water drainage plug. It is
recommended to be cleaned once every 1-2 months
9. Dry the filter and filter assembly and the water curtain before re-assembling.
10. To clean the exterior surfaces simply wipe over with a soft damp cloth. Should it
be necessary, greasy marks may be removed from the surfaces by using mild
soap and a cloth dampened in hot water. Avoid all other types of detergents,
cleaners and solvents that may contain chemicals which could damage parts of
the unit. Thoroughly dry all parts before storage.
11. Store in a cool dust free location for next use.
PROBLEMS
Always check full product operation as detailed above before returning any
product as faulty.
On humid days the unit may not appear to be cooling correctly. This is due to the
air already being saturated with water. Adding more water to the air will not result
in pulling the air temperature down. In these conditions, it is advisable to operate
the unit as a fan only to circulate room air.

FOR YOUR SAFETY

Always operate the unit as detailed above.
CAUTION: To reduce the risk of electric shock, DO NOT remove the cover (or
back) while the unit is in operation or connected to the mains supply.