Electrical Data; Tested Combination Ratings; Sound Rating (Dba) - Carrier 38YXA Preliminary Product Fact Sheet

13 seer split-system heat pump with r-410a
Table of Contents

Advertisement

UNIT
V/PH
SIZE-SERIES
024-30
030-30
036-30
208/230/1
042-30
048-30
060-31
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG)
is used, consult applicable tables of the NEC (ANSI/NFPA 70).
If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name
ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-30.
‡ Length shown is as measured 1 way along the wire path between the unit and the service panel for a voltage drop not to exceed 2 percent.
** Time-delay fuse.
FLA—Full Load Amps
LRA—Locked Rotor Amps
MCA—Minimum Circuit Amp
RLA—Rated Load Amps
NOTE: 1. Control circuit is 24v on all units and requires external power source.
2. Copper wire must be used from service disconnect to unit.
3. All motors/compressors contain internal overload protection.
UNIT SIZE-
INDOOR
SERIES
UNIT
024-30
FX4ANF030
030-30
FX4ANF030
036-30
FX4ANF042
042-30
FV4ANF003
048-30
FV4ANF005
060-31
FV4ANB006
* Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
† Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temp Heating Standard: 70°F (21°C) db indoor entering air temperature and 17°F (-9°C) db 15°F (-10°C) wb air entering outdoor unit.
‡ In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either
the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Carrier furnaces are equipped with TDR except for the 58GFA.
** Based on computer simulation. TXV must be R-410A compatible and hard shutoff type.
COP—Coefficient of Performance
EER—Energy Efficiency Ratio
HSPF—Heating Seasonal Performance Factor
SEER—Seasonal Energy Efficiency Ratio
TC—Total Capacity (Btuh)
TDR—Time-Delay Relay
TXV—Thermostatic Expansion Valve
OPER VOLTS*
COMPRESSOR
Max
Min
LRA
61.0
72.5
83.0
253
187
104.0
109.0
158.0

Tested Combination Ratings*

Factory-
TC
Supplied
Standard
Enhance-
Rating
ment
25,000
TDR & TXV
13.00
29,000
TDR & TXV
13.00
35,000
TDR & TXV
13.00
40,500
TDR & TXV
13.10
45,500
TDR & TXV
13.50
58,500
TDR & TXV
13.20

Sound Rating (dBA)

UNIT SIZE-SERIES
024-30
030-30
036-30
042-30
048-30
060-31

Electrical Data

60°C
FAN
MIN
MCA
FLA
WIRE
RLA
SIZE†
15.1
0.8
19.7
14
14.7
1.1
19.5
14
15.4
1.1
20.4
12
21.1
1.1
27.5
10
20.5
1.4
27.0
10
27.6
1.4
35.9
8
ARI STANDARD RATINGS†
Cooling
SEER
Carrier
Gas
Furnace
Accessory
or
TXV**
Accessory
TDR‡
SOUND RATING
4
75°C
60°C
75°C
MIN
MAX
MAX
WIRE
LENGTH
LENGTH
SIZE†
(FT)‡
(FT)‡
14
39
37
14
39
37
12
60
57
10
71
68
10
74
70
8
86
82
Heating
High-Temp
Low-Temp
EER
TC
COP
TC
11.50
25,000
3.30
16,600
11.40
30,000
3.50
18,500
11.30
35,000
3.35
21,600
11.30
40,500
3.35
25,400
12.00
47,500
3.50
28,300
11.00
60,000
3.50
37,000
70
72
74
73
76
76
MAX FUSE**
OR
CKT BKR
AMPS
30
30
30
40
40
60
HSPF
COP
2.30
8.00
2.34
8.00
2.34
7.70
2.45
7.70
2.50
8.50
2.53
8.00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents