Accessories; Accessory Usage Guideline - Carrier 38YXA Preliminary Product Fact Sheet

13 seer split-system heat pump with r-410a
Table of Contents

Advertisement

ORDERING NO.
KAATD0101TDR
KSALA0301410
KAAFT0101AAA
KHAIR0101AAA
KSAHS1501AAA
KSAHS1601AAA
KAACS0201PTC
KAACH1201AAA
Standard
KHAOT0301FST
KHAOT0201SEC
KHASA0101AAA
KHAIC0101AAA
KSATX0201HSZ
KSATX0301HSZ
KSATX0401HSZ
KSATX0501HSZ
KH45LG140 (RCD)
KH45LG141 (RCD)
KHALS0401LLS
KSASF0101AAA
KHASS0206MPK
THERMOSTAT/SUBBASE PKG
TSTATCCNHP01-A
TSTATCCPHP01-A
TSTATCCPDF01-A
TSTATCCPRH01-A
--HH--07AT-215
TSTATXXSEN01
TSTATXXNBP01
TSTATXXPBP01
TSTATXXCNV10
ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Compressor Start Assist—Capacitor and Relay
R-410A Low-Ambient Pressure Switch
Wind Baffle
Support Feet
R-410A Hard Shutoff TXV
R-410A Liquid-Line Solenoid Valve for Heating
* For tubing line sets between 50 and 175 ft, refer to the Application Guideline and Service Manual for Residential Split-System Air Conditioners and Heat Pumps using
R-410A Refrigerant.
† Required for all applications.

Accessories

Time-Delay Relay—All Sizes
Low-Ambient Pressure Switch—All Sizes
Evaporator Freeze Thermostat—All Sizes
Isolation Relay—All Sizes
Start Assist—Capacitor and Relay—Sizes 024–042
Start Assist—Capacitor and Relay—Size 048, 060
Start Assist—PTC—All Sizes
Crankcase Heater—Sizes 024–042
Crankcase Heater—Sizes 048, 060
Outdoor Thermostat—All Sizes
Secondary Outdoor Thermostat—All Sizes
Service Alarm—All Sizes
Interface Control (Optimizer II®)—All Sizes
Bi-Flow TXV (Hard Shutoff)—Sizes 024, 030
Bi-Flow TXV (Hard Shutoff)—Sizes 036, 042
Bi-Flow TXV (Hard Shutoff)—Size 048
Bi-Flow TXV (Hard Shutoff)—Size 060
Bi-Flow Filter Drier (Suction Line)—Sizes 024–036
Bi-Flow Filter Drier (Suction Line)—Sizes 042–060
Liquid-Line Solenoid Valve—All Sizes
Support Feet—4 In. (4)—All Sizes
Snow Stand—18 In.—All Sizes
Thermostat—Auto Changeover, Non-Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool
Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1-Stage Cool
Thermostat—Auto Changeover, 7-Day Programmable, °F/°C, Dual Fuel
Must be used with Outdoor Air Temperature Sensor (TSTATXXSEN01)
Thermidistat™ Control—Programmable Thermostat with Humidity Control
Thermostat—Manual Changeover, Non-Programmable, °F, 2-Stage Heat, 1-Stage Cool
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Thermostat Conversion Kit (4 to 5 Wire)—10 Pack

Accessory Usage Guideline

REQUIRED FOR LOW-AMBIENT
Pressure Switch Instructions
DESCRIPTION
DESCRIPTION
APPLICATIONS
(BELOW 55°F)
Yes
Yes
Yes
Yes
See Low-Ambient
Recommended
Yes†
No
3
REQUIRED FOR LONG-LINE
APPLICATIONS*
(OVER 50 FT)
Yes
No
Yes
No
No
No
Yes†
See Long-Line
Application Guideline