5 - ELECTRICAL DATA

61AF - Standard unit (without hydraulic module)
Power circuit
Nominal power supply
Voltage range
Control circuit supply
Maximum start-up current (Un)
Standard unit
Unit with electronic starter option
Unit power factor at maximum capacity
Maximum unit power input
Nominal unit current draw
(3)
Maximum unit current draw (Un)
Maximum unit current draw (Un-10%)*
Customer-side unit power reserve
Short-circuit stability and protection
(1) Maximum instantaneous start-up current (maximum operating current of the compressor + fan current + locked rotor current of the compressor).
(2) Power input, compressor and fan, at the unit operating limits (saturated suction temperature 10 °C, saturated condensing temperature 65 °C) and nominal voltage of
400V (data given on the unit nameplate).
(3) Standardised Eurovent conditions: evaporator entering/leaving water temperature 40 °C/45 °C, outside air temperature db/wb = 7 °C/6 °C.
(4) Maximum unit operating current at maximum unit power input and 400 V (values given on the unit nameplate).
*
Maximum unit operating current at maximum unit power input and 360 V.

5.1 - Compressor usage and electrical data for standard units

Compressor
I Nom
ZH18KVE
10,8
ZH24KVE
13,6
ZH33KVE
17,3
ZH40KVE
20,4
ZH48KVE
24,9
Legend
I Nom  
Nominal current draw at Eurovent conditions (see definition of conditions under nominal unit current draw), A
I Max
Maximum operating current at 360 V, A
(1)
Locked rotor current at nominal voltage, A
(2
Locked rotor current at nominal voltage, electronic starter

5.2 - Short-circuit stability current (TN system

fuse)
61AF
Value without upstream protection
Short-term current at 1 s - Icw - kA rms
Admissible peak current - Ipk - kA pk
Maximum value with upstream protection by circuit
breaker
Conditional short-circuit current Icc - kA rms
Circuit breaker - Compact range
Reference number
(2)
Value with upstream protection (fuses)
Conditional short-circuit current Icc - kA rms
Fuse (gL/gG)
(1) Earthing system type
(2)  If  another  current  limitation  protection  system  is  used,  its  time-current  and  thermal  constraints  (l²t)  trip  characteristics  must  be  at  least  equivalent  to  those  of  the 
recommended circuit breaker.
The short circuit stability current values above are suitable with TN system.
(1)
(2)
(2)
(4)
I Max
I Max
LRA
(Un)
(Un-10 %)
A
14,0
15,6
101
18,3
20,3
99
24,2
26,9
127
30,0
33,2
167
36,0
40,0
198
V-ph-Hz
V
A
A
kW
A
A
A
LRA
Cosine
(1)
(2)
A
phi max
53
0,84
51
0,85
66
0,85
87
0,89
97
0,89
) - standard unit (with main disconnect without
(1)
022
030
0.6
0.6
4.5
4.5
5.4
7
32
40
5SY6332-7 5SY6340-7 5SY6340-7 5SY4350-7 5SY4363-8 5SP4380-7 5SP4391-7
17
50
40
40
022
030
035
045
400-3-50
360-440
24 V, via internal transformer
104
102
130
170
56
55
70
91
0,82
0,82
0,82
0,82
9
12
15
19
14
16
20
23
16
20
26
32
18
22
29
35
Customer reserve at the 24 V control power circuit
See table on the next page
22
30
35
45
1
-
-
-
-
1
-
-
-
-
1
-
-
-
-
1
-
-
-
-
035
045
055
0.6
1.26
1.26
4.5
6
6
7
7.7
7.7
40
50
63
50
50
50
40
63
63
055
075
105
201
157
241
101
101
142
0,82
0,82
0,82
23
30
46
28
40
55
38
53
76
42
57
83
55
75
105
-
-
-
-
-
-
-
2
-
-
-
-
1
-
2
075
105
1.26
2
6
10
6.1
10
80
100
14.5
22
80
125