Carrier 38YCC Series Product Data

Carrier 38YCC Series Product Data

50 hz 10 seer export model sizes 18-60 1-1/2 to 5 nominal tons (7 to 17.5 kw)
Hide thumbs Also See for 38YCC Series:

Advertisement

38YCC (50 Hz)
10 SEER Heat Pump
Export Model
Sizes 18 --- 60
1---1/2 to 5 Nominal Tons (7 To 17.5 kW)
The 38YCC Outdoor Section of Split- -System Heat Pumps is
designed for quiet, reliable heating during the winter and cooling
during the summer. With EER ratings up to 9.0, this heat pump
system
provides
economy
conservation when used with components designated by Carrier.
The 38YCC recovers heat for indoor comfort from outdoor air
during the heating season and, by automatically reversing the
refrigerant system, removes indoor heat and excess humidity
during the cooling season.

Product Data

of
operation
through
energy

FEATURES AND BENEFITS

Electrical Range

Single- -phase units are available in sizes 018, 024, and 036 in 230v
50 Hz. Three- -phase units are available in sizes 036, 048, and 060
in 400v 50 Hz.
Wide Range of Sizes
The 38YCC is available in nominal sizes 018, 024, 036, 048 and
060 to meet the needs of residential and light commercial
applications.

Unit Design

All units are equipped with totally enclosed fan motors for greater
reliability
under
adverse
wrap- -around coil uses copper tube and enhanced epoxy coated
aluminum fin and is designed for optimum heat transfer and
corrosion protection during heating and cooling. The vertical air
discharge carries the sound and air up and away from adjacent
patio areas and foliage. Coil can be cleaned with a common garden
hose.
Weather- -Protective Cabinet
A weather protective cabinet of pre- -painted steel is protected
underneath by a zinc galvanized coating for a finish that will last
for many years. All screws on cabinet exterior are coated for a
long- -lasting, rust- -resistant, quality appearance.

Compressor

Designed specifically for heat pump duty, with energy efficiency
during heating and cooling operation. The compressor is
hermetically sealed against contamination to assure long life and
dependable
performance,
reciprocating compressor), and externally mounted on rubber
isolators for quiet operation. For improved serviceability, all
models are equipped with a compressor terminal plug.
Compressor Protection
Each compressor is protected with internal temperature- - and
current- -sensitive overloads.
Reliable standard components
Includes a suction- -tube accumulator that reduces the amount of
liquid refrigerant that reaches the compressor; a high pressure
switch to prevent excessive pressure build- -up; a low- -pressure
switch to stop the compressor if refrigerant charge is lost; a
Crankcase Heater to keep compressor oil warm and free of
refrigerant for maximum lubricity; an internal compressor relief
valve for high- -pressure protection; and 5- -minute compressor
delay.
3- -phase monitor board
Control board that monitors the electrical phase and prevents
compressor operation if wired incorrectly. Standard on 048 and
060 3 phase equipment.
weather
conditions.
The
internally
sprung
(units
(scroll compressor models)
large,
with

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 38YCC Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 38YCC Series

  • Page 1: Product Data

    50 Hz. Three- -phase units are available in sizes 036, 048, and 060 in 400v 50 Hz. Wide Range of Sizes The 38YCC is available in nominal sizes 018, 024, 036, 048 and 060 to meet the needs of residential and light commercial applications.
  • Page 2: Physical Data

    FEATURES AND BENEFITS (CONT.) External Service Valves Discharge Muffler Service valves are brass, front seating type. The 38YCC has sweat Minimizes low frequency sound and pressure pulsation generated field connections. Valves are externally located so refrigerant tube by compressor discharge gas.
  • Page 3: Electrical Data

    ELECTRICAL DATA OPER VOLTS* COMPRESSOR WIRE LENGTH MAX FUSE† LENGTH OUTDOOR V/PH SIZE** (Ft)‡ OR CKT (m)‡ UNIT 60˚C/ 60˚C/ BKR AMPS 60˚C/ 75˚C 75˚C 75˚C 018--- 7A 55.0 0.52 11.5 14/14 66/62 20.1/18.9 024--- 7A 230 ---1 68.0 11.5 0.52 14.9 14/14...
  • Page 4 Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non ---programmable air conditioner version and builder;s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
  • Page 5 ACCESSORY USAGE GUIDELINE REQUIRED FOR REQUIRED FOR LONG LINE REQUIRED FOR SEA COAST ACCESSORY LOW --- AMBIENT APPLICATIONS APPLICATIONS* APPLICATIONS (Below 55° F / 12.78° C) (Over 80 Ft. / 24.38 m) (Within 2 miles / 3.22 km) Accumulator Ball Bearing Fan Motor Yes{ Compressor Start Assist Yes{...
  • Page 6 Heat pump installations in areas of prolonged 12. Outdoor Air Temperature Sensor subfreezing temperatures. Designed for use with Carrier Thermostats listed in this All commercial installations. publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special 17.
  • Page 9 BTU/HR 1000 CAPACITY, HEATING INTEGRATED UNIT BTU/HR 1000 LOSS, HEAT BUILDING...
  • Page 10 CAPACITY, HEATING INTEGRATED UNIT LOSS, HEAT BUILDING...
  • Page 11 COMBINATION RATINGS* Cooling Capacity @ 95˚F (35˚C) Heating Capacity NOMINAL OUTDOOR AIR--- FLOW High--- Temp @ 47˚F (8˚C) Low--- Temp @ 17˚F (--- 8˚C) UNIT INDOOR UNIT Rated Capacity Power Rated SIZE--- Rated Capacity Power Rated Capacity Power BTUH SERIES BTUH BTUH FB4BSF018...
  • Page 24: Guide Specifications

    R- -22 refrigerant, compressor oil, accumulator, and reversing valve. Catalog No.38YCC ---C8PD Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/07 Replaces:38YCC--- C7PD...