Horizontal Termination - Majestic DV6000 Installation And Operating Instructions Manual

Direct vent gas fireplace
Table of Contents

Advertisement

DV6000 Gas Fireplace
For horIZontal terMInatIon
D
E
B
L
Vent Terminal
V
MInIMuM dIstances
A = Clearance above the grade, a veranda, porch, deck, or balcony [*1" (305 mm) minimum].
B = Clearance to window or door that may be opened [*1" (305 mm) minimum].
C = Clearance to permanently closed window [*minimum 1" (305 mm) recommended to prevent condensation
on window]
D = Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of two ()
feet (610mm) from the centerline of the terminal [18" (457 mm) minimum].
E = Clearance to unventilated soffits [1" (305 mm) minimum]. clearance to vinyl soffit [30" (762mm)].
F = Clearance to an outside corner. See page 14.
G = Clearance to an inside corner. See page 14.
H = *Not to be installed above a gas meter/regulator assembly within three (3) feet (914mm) horizontally from
the centerline of the regulator.
I = Clearance to service regulator vent outlet [*3' (914 mm) minimum].
J = Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance
[*1" (305 mm) minimum].
K = Clearance to a mechanical air supply inlet [*6' (189 mm) minimum].
L = Clearance above a paved sidewalk or paved driveway located on public property [
minimum].
M = Clearance under veranda, porch, deck, or balcony [*1" (305 mm) minimum
N = Clearance above a roof shall extend a minimum of 4" (610 mm) above the highest point when it passes
through the roof surface and any other obstruction within a horizontal distance of 18" (457 mm).
*
As specified in CSA B149 Installation Codes. Note: Local codes or regulations may require different
clearances.
** A vent must not terminate directly above a sidewalk or paved driveway, which is located between two
single-family dwellings and serves both dwellings.
*** Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the
floor.
always maintain minimum clearances around vent systems. the minimum clearances
to combustibles for horizontal vent pipe are 3" at the top and 1" at the sides and bottom
of the vent system until the pipe penetrates the nearest vertical wall. a 1" minimum
clearance all around the pipe must be maintained. do not pack the open air spaces with
insulation or other materials. this could cause high temperatures and may present a
fire hazard.
18
C
B
B
V
Fixed
Closed
Opera-
V
F
ble
Operable
V
B
A
Air Supply Inlet
A
H
B
I
Fixed
V
Closed
V
A
B
J
Area Where Terminals Not Permitted
vent InstallatIon
Inside Corner Detail
G
V
A
G
M
V
A
A
K
**
***
].
7' (133 mm)
53D0419