Bertazzoni PRO30 4 DFS X Installation, Use & Care Manual page 16

30” freestanding dual fuel ranges
Table of Contents

Advertisement

4) Loose strain relief by unscrewing the two 
strain relief's screws as in diagram. 
 
 
 
 
 
 
 
 
5)   Remove  damaged  supply  cord  set  by  taking 
off  the  4  electrical  connection  screws  (block 
L1, N, L2 and Ground screw, see diagram) 
6)   Insert  the  new  supply  cord  set  in  the  strain 
relief  and  lock  it  with  two  strain  relief's 
screws in suitable position. 
7)   Fix well the ring terminals G, L1, N, L2 of the 
new  supply  cord  set  as shown  in  diagram 
with its 4 screws 
8)   Re‐install  the  back  enclosure  panel  with  6 
screws 
9)   Slide  the  appliance  back  into  its  proper 
location 
10)  Re‐connect  the  appliance  to  the  electrical 
power. 
 
ELECTRICAL GROUNDING 
This appliance is equipped with a four‐prong plug 
for  your  protection  against  shock  hazard  and 
should  be  plugged  directly  into  a  properly 
grounded  receptacle.  Do  not  cut  or  remove  the 
grounding prong from this plug. 