Dimensions - Phonic XP 600 User Manual

Hide thumbs Also See for XP 600:
Table of Contents

Advertisement

Available languages

Available languages

Stereo Mode (both channels driven)
8 ohms FTC 20Hz-20kHz 0.1% THD
4 ohms FTC 20Hz-20kHz 0.1% THD
2 ohms FTC 20Hz-20kHz 0.1% THD
8 ohms EIA 1kHz 0.1% THD
4 ohms EIA 1kHz 0.1% THD
2 ohms EIA 1kHz 1% THD
Bridge Mono Mode
8 ohms FTC 20Hz-20kHz 0.1% THD
8 ohms EIA 1kHz 0.1% THD
4 ohms EIA 1kHz 1% THD
All Models
Subwoofer output
Distortion (SMPTE-IM)
Distortion (Typical) 20Hz-20kHz: 10dB below
rated power
Distortion (Typical) 1kHz and below: full rated
power
Frequency Response
Damping Factor
Noise (unweighted)
Input sensitivity
Control Font
Control Rear
Voltage Gain
Input Impedance
Indicators
Connectors Input
Connectors Output
Cooling
Amplifier Protection
Load Protection
Output Circuitry
Power Requirements (depends on region)
Circuit Breakers
Dimensions (WxHxD)
Weight
XP 600/1000/2000/2100/3000/3100/5000/5100
Continuous Average Output Power Per Channel
Continuous Average Output Power
Selectable subwoofer crossover at 60Hz, 90Hz, 120Hz
20Hz-20kHz, 8 ohms, LF filter bypassed, +0/-1dB
5Hz to 50kHz, 8ohms, LF filter bypassed, +0/-3 dB
100 dB below rated output (20 Hz to 20kHz, 8 ohms load)
1.42 Vrms for 1000 watts into 8 ohms
AC power switch, Ch1 & Ch2 gain control with 41 detents
12-pole DIP switch featuring high pass filter on/off, high pass filter 30/50Hz, Clip Limiter
on/off control for each channel and switches for selecting Stereo, Parallel, or Bridge
Mode. Push-button circuit breaker for each channel. Slide switch for Grounding / Float-
ing (Selectable low pass filter frequency at 60Hz, 90Hz and 120Hz, XP5100 only)
20k ohms balanced, 10k ohms unbalanced
Power-On: Amber Phonic logo; Parallel: Green backlight icon; Bridged: Red backlight
icon; CLIP/LIM: Red LED;
PROTECT: Yellow LED Green LED for -10dB, -20dB and -40dB Signal Lights
XLR, 1/4"TRS jacks and barrier strip
Binding posts and speakon outputs (Ch1 speakon wired for biamp)
Continuous variable-speed fan, rear-to-front air flow
Short circuit, open circuit, thermal, ultrasonic, and RF protection. Stable into mis-
on/off muting, DC fault output crowbar
100-120VAC, 220-240VAC (+/- 10%), 50/60Hz (factory configured); 120V model
two (one for each channel): 100 and 120V models: 20 amp / 230 V models: 10 amp
482 x 150 x 400mm (19" x 5.9" x 15.7")
XP5000 / 5100
1050W
1600W
2000W
1100W
1800W
2500W
3200W
3600W
5000W
(XP5100 only)
<0.02%
<0.02%
<0.02%
>250 @ 8 ohms
41x (36dB)
matched loads
Calss H Amplifier
requires 20 amp
30.2 kg (66.6 lbs)
7
7