INSTALLATION INSTRUCTIONS

ELECTRICAL INSTALLATION

WARNING: ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A LICENSED, LOCALLY CERTIFIED ELECTRI-
CIAN, IN ACCORDANCE WITH THE REQUIREMENTS OF THE NATIONAL ELECTRICAL CODES AND PROCEDURES.
WARNING: WHEN USING ELECTRICAL PRODUCTS, PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING
THE FOLLOWING:
DANGER: RISK OF ELECTRIC SHOCK!
Infinity baths will need to be hard wired to the outlets provided. See the following directions and diagram.
Two junction boxes will be mounted to the frame of the whirlpool. One of the two boxes will have one outlet and will be
labeled "Blower". Remove the cover and connect a 14/2 with ground Romex wire from a 15 amp 1-pole GFCI breaker
(not supplied) in the main circuit breaker panel. Connect the black wire to the hot side of the receptacle, the white wire to
the neutral side of the receptacle and the green wire to ground. Replace the cover and plug in the blower. (See diagram
on page 11).
The second junction box will have two outlets, one labeled "Main" and the other labeled "Heater". Remove the cover. Run
Romex 14/3 with ground from a 15 amp 2-pole GFCI breaker (not supplied) located in the breaker panel. Connect the white
wire (neutral) to both neutrals of the two outlets. Connect the red wire (hot) to the hot terminal of the outlet labeled "Main".
Connect the black wire (hot) to the hot terminal of the other outlet labeled "Heater". Connect the green wire (ground) to the
ground terminal of the outlet. Replace the cover of the junction box. Find the cord labeled "Heater AC Input" and plug it
into the outlet labeled "Heater". Plug the cord labeled "Main AC Input" into the outlet labeled "Main". Both of these cords
will come from the right side of the heater and will be marked. (See diagram on page 11).
CAUTION: Before use of the pump and heater, test the GFCI for proper operation. The pump and heater should turn off
when the GFCI "Test" button is pushed.
WARNING - Prolonged Immersions in Hotter Water May Induce Hyperthermia.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body
temperature of 98.6
F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness,
o
lethargy, drowsiness, and fainting. The effects of hyperthermia include (1) failure to perceive heat, (2) failure to recognize
the need to exit the whirlpool, (3) unawareness of impending hazard, (4) fetal damage in pregnant women, (5) physical
inability to exit the whirlpool, (6) unconsciousness resulting in the danger of drowning.
WARNING - The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia.
TO REPLACE THE LED LIGHT
1. Disconnect the power to your bathtub.
2. Drain the bathtub.
3. Open the lens of the fixture using ONLY the proper tool provided
for that purpose. Do not attempt to remove the lens
without the provided tool.
4. Replace your LED light (replacement LED lights can be obtained from
Aquatic).
NOTE: Do not twist LED light into socket. Use gentle pressure and push
LED light into place.
10
GFCI's are not supplied, however we do specify their use.
All known code authorities require GFCI's.