Advertisement

Engaging/Disengaging Hand
Activated Wheel Locks
NOTE: For this procedure, refer to 
FIGURE 10.3.
1. Push handle forward away from tire to 
engage wheel locks.
2. Pull handle back toward tire to 
disengage wheel locks.
3. Only 12‐inch rear wheel shown for 
clarity.

Adjusting the Wheel Lock

NOTE: For this procedure, refer to FIGURE 10.4 on page 68.
NOTE: Before adjusting the wheel lock assemblies, ensure that the tires are inflated to the 
recommended P.S.I. on the side wall of the tire.
1. Loosen the two socket screws that secure the wheel lock assembly to the wheelchair 
frame.
NOTE: Any wheel lock adjustment should embed the wheel lock shoe at least 3/16‐inch into the 
tire when engaged.
2. Adjust the position of wheel lock until the 3/16‐inch measurement is obtained for 
correct wheel lock adjustment.
3. Securely tighten the two socket screws.
4. Repeat procedure for opposite wheel lock.
5. Engage the wheel lock and push against the wheelchair and determine if the wheel 
lock engages the wheel lock shoe enough to hold the wheelchair.
6. Repeat the STEPS 1‐5 until the wheel lock holds the wheelchair.