SPA TROUBLE SHOOTING GUIDE

NOThINg ON The Spa OpeRaTeS-
1. Check the control panel display for any messages. If there is a message, refer to the diagnostic sec-
tion on that model spa. There you will find the meaning of the message and what action is to be
taken.
2. If there is no message on your control panel, check and reset the GFCI and house breaker.
If the spa does not respond, contact your local service company.
pUmp(S) dO NOT OpeRaTe -
1. Press the "jets" button on your control panel.
If you hear the pumps trying to operate:
A. Check that all the slice valves are open. See photo on page 13.
B. Pump may need to be primed. See page 17.
C. Check that the air controls are open. See photo on page 11.
If you do not hear anything from the pump, contact your local service company.
pOOR JeT peRfORmaNce
1. Make sure pump is operating
2. Check that the water level is adequate (up to minimum safe water level side)
3. Make sure the jets are open and the air controls are open. See page 11.
4. Check for dirty filters. Clean if necessary.
DO NOT DIVE.
* The GFCI should be located in a weather proof box close to the spa,
but no closer than 5 ft.
48