Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
0B94
IPMB signal lines not
reponding.
0B95
BMC FRU device
failure.
0B96
BMC SDR
Repository failure.
BMC SEL device
0B97
failure.
0B98
BMC RAM test
error.
0B99
BMC Fatal hardware
error.
Management
0B9A
controller not
responding.
0B9B
Private I2C bus not
responding.
0B9C
BMC internal
exception.
0B9D
BMC A/D timeout
error.
0B9E
SDR repository
corrupt.
0B9F
SEL corrupt.
0BB0
SMBIOS - SROM
data read error.
0BB1
SMBIOS - SROM
data checksum bad
0BC0
POST detected
startup failure of
CPU #1.
0BC1
POST detected
startup failure of
CPU #2.
5-18 Problem Solving
Description
Access to SROM that contains the
chassis information failed.
Access to FMEM sector that
contains SDR information failed.
Possible BMC errors.
Read error of SROM data.
Checksum for the SROM data is
incorrect.
CPU #1 failed to startup.
CPU #2 failed to startup.
Action
All the functions other than the function
of accessing to SMC through IPMB can
be used. This is not a fatal error. Turn
off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.
All the commands and functions other
than the FRU command and the EMP
function can be used. This is not a fatal
error. Turn off the power once and
then on again to restart the server. If the
error cannot be corrected, contact your
service representative.
Turn off the power once and
then on again to restart the server. If
the error cannot be corrected, contact
your service representative.
Contact your service representative to
replace the failed CPU.