Adjustment
11

Adjusting the automatic presser foot lift -910/06

.08
11 - 30
Requirement
When the automatic presser foot lift is operated, the clearance between the presser foot
and the needle plate must be 9 mm for a small needle bar stroke and 13 mm for a large
needle bar stroke.
2
Fig. 11 - 29
Move magnet 1 (screw 2) according to the requirement.
1