6.9.3

Circulation pump

Access to the pump is from the base of the appliance:
a. Remove the two screws which secure the pump to the base.
b. Detach the circulation pump assembly from the base.
c. Loosen the clamps and detach the hoses from the pump (Fig. 40).
d. Detach the cover.
e. Detach the wiring connectors.
f.
Remove the circulation pump assembly.
6.9.4

Drain filter body

a. Remove the rear cabinet shell.
b. Lay the appliance face-down.
c. Remove the circulation pump (if present).
d. Detach the hoses from the filter body.
e. Remove the screws which secure the front shell to the base.
(Fig.41)
f.
Raise the base in order to detach the filter body from the front
shell.
g. Release the tabs which anchor the filter body to the base.
(Fig.37)
h. Remove the drain pump.
i.
Remove the filter body.
6.9.5

Base

a. Remove the rear cabinet shell.
b. Remove the pins which secure the dampers to the base.
c. Cut the fixing ties and detach the wiring.
d. Lay the appliance face-down.
e. Detach the drain hose.
f.
Remove the lateral screws which secure the front shell
to the base. (Fig.41)
g. Remove the lateral screws which secure the front shell
to the base. (Fig.42)
h. Raise the base and remove the filter body.
i.
Remove the base.
After re-assembly, connect the wiring correctly to the base and secure using new wiring ties.