Blow Setting - Gree XK41 Owner's Manual

Wired controller
Hide thumbs Also See for XK41:
Table of Contents

Advertisement

3.10 Blow Setting

Blow function: After the unit is turned off, the water in evaporator of indoor unit will be
automatically evaporated to avoid mildew.
In the Cooling or Dry mode, press Function till the unit enters the Blow setting status and then
press Enter/Cancel to active this function.
When the Blow function is activated, press Function to the Blow setting status and then press
Enter/Cancel to cancel this function.
Blow function setting is as shown in Fig.3.10.1
Notes:
W hen the Blow function is activated, if turning off the unit by pressing On/Off or by the
① .
remote controller, the indoor fan will run at the low fan speed for 2 min, with "BLOW" displayed on
the LCD. While, if the Blow function is deactivated, the indoor fan will be turned off directly.
B low function is unavailable in the Fan or Heating mode.
② .
Fig.3.10.1 Blow Setting
11
Wired Controller XK41 & XK47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xk47

Table of Contents