F. Install Refractory
We recommend two installers for hearth stone and re-
fractory installation!
Remove smoke shield by removing five screws (starting
from one side: remove two, skip one, remove one, skip
one, remove two). See Figures 7.9 and 7.10.
Figure 7.9
Remove Smoke Shield
Front Face
Skip
Remove these screws.
Figure 7.10 Remove Smoke Shield
Position the bottom of the back refractory to the back
of the fireplace and center from side to side. See
Figure 7.11. Be sure to position it so the retainer notch
is at the top.
Figure 7.11 Install Back Refractory
Smoke Shield
Skip
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev Y • 1/11
Fasten in place with the refractory retainer and screws
provided. See Figure 7.12.
Figure 7.12 Attach Back Refractory
Note: To ensure proper installation, gas knockouts in
the side refractories should be positioned towards back
of fireplace. See Figure 7.13.
Place side refractory into fireplace. Position towards
front of fireplace and slide to the rear. See Figures 7.13
and 7.14. Repeat for the second side refractory.
Figure 7.13 Install Side Refractory
Figure 7.14 Side Refractory Installed
REFRACTORy
RETAINER