Heat & Glo EXCLAIM-50 Owner's Manual page 36

Wood burning fireplace
Hide thumbs Also See for EXCLAIM-50:
Table of Contents

Advertisement

TR11T Round Telescoping Termination Cap
Assemble
Termination
storm collar
around extended
termination cap
pipe
once cap is
installed.
Caulk gaps between
storm collar & pipe,
and storm collar
& chase top.
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)
Figure 9.5
Installing a TR11T Round Telescoping Termination
Cap
ST1175 Square Termination Cap
Flange
Termination Cap
Collar
2 in. (51 mm)
Minimum Height
Chase Top
Chimney
Pipe
Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)
Figure 9.6
Installing an ST1175 Square Termination Cap
36
Cap
Do NOT
block air
holes
Storm
Collar
3 clip brackets.
Slip over chase collar
and attach with screws
provided.
14 1/2 in. (368 mm)
Maximum
Chase
Chimney
Pipe
Place waterproof
caulk or sealer under
each flange of the
termination cap and
on top of each screw
to help prevent leaks.
The last section of pipe
must stop between 2 in. (51
mm) above the top of the
chase and 4 3/4 in. (121
mm) below the top of the
chase.
2 in. (51 mm)
maximum
4 3/4 in. (121 mm)
Chase
Heat & Glo • EXCLAIM-50 • 4013-041 • Rev Y • 1/11
TCT1175 Terra Cotta Cap
Remove 2 screws
from front & back
to lift the top off
2 in. (51 mm)
Minimum Height
Termination cap pipe and chimney section must overlap
Figure 9.7
maximum
Termination Cap
Collar
Chase Top
Chimney
Pipe
1-1/2 in. (38 mm)
Installing a TCT1175 Terra Cotta Cap
Place waterproof sealer
under each flange of the
termination cap and on
top of each screw to
help prevent leaks.
The last section of pipe
must stop between 2 in.
(51 mm) above top of
chase and 7 in. (178 mm)
below top of chase
2 in. (51 mm)
7 in. (178 mm)
Chase

Advertisement

Table of Contents
loading

Table of Contents