Maintenance And Service; Maintenance Tasks-Homeowner - Heatilator RBV4236IH Owner's Manual

Fireplace
Hide thumbs Also See for RBV4236IH:
Table of Contents

Advertisement

3
Maintenance and Service
Any safety screen or guard removed for servicing must be
replaced prior to operating the fireplace.
When properly maintained, your fireplace will give you
many years of trouble-free service. We recommend an-
nual service by a qualified service technician.
A. Maintenance Tasks-Homeowner
Installation and repair should be done by a qualified service
technician only. The fireplace should be inspected before use
and at least annually by a professional service person.
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service ap-
pointment.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the fireplace must be
kept clean.
CAUTION! Risk of Burns! The fireplace should be
turned off and cooled before servicing.
Doors, Surrounds, Fronts
Frequency: Annually
By: Homeowner
Tools needed:
Protective gloves, stable work surface
Assess condition of glass and replace as necessary.
Inspect for scratches, dents or other damage and repair
as necessary.
Vacuum and dust surfaces.
Heatilator • RBV4236/RBV4842 • 4048-210 • Rev S • 6/10
Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote control in-
structions.
Locate remote control transmitter and receiver.
Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
Place batteries as needed in remote transmitters and
battery-powered receivers.
Place remote control out of reach of children.
If not using your fireplace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
Remove batteries from remote controls.
Unplug 3 volt adapter plug on IPI models.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed:
Protective gloves and safety glasses.
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
Inspect for corrosion or separation.
Verify weather stripping, sealing and flashing remains
intact.
Inspect draft shield to verify it is not damaged or missing.
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbv4842ihRbv4842itRbv4236it

Table of Contents