FRAMING INFORMATION
CLEARANCE TO COMBUSTIBLES
Sides .......................................................... 1/2"
Back ........................................................... 1/2"
Top ................................................................ 0"
Front ............................................................ 37"
Bottom ........................................................... 0"
When the fireplace is installed directly on carpeting, vinyl tile or other combustible materials (other than
wood flooring), it shall be installed on a metal or wood panel extending the full width and depth of the
fireplace.
Provide adequate ventilation air.
Provide adequate accessibility clearance for servicing and operating the fireplace.
Never obstruct the front opening of the fireplace.
MANTEL CLEARANCES
Figure 3
53D9009
Combustible Mantel
and Trim Allowed
Above Dotted Line
12"
Measure from
Top of Opening
Front of Fireplace
8 "
2 "
9"
FP2206
mantel clearance
B-Vent Specialty Gas Fireplaces
FP2206
9