Pre-Installation Information; High Elevations; Pressures And Btu's; Before You Install - MHSC BVST/BVSTE Installation & Operating Instructions Manual

B-vent specialty series natural vent gas fireplaces
Table of Contents

Advertisement

B-Vent Specialty Gas Fireplaces

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certified without deration for elevations up to
4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installation must be in accordance with the
current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiciton for installation at
elevations above 4,500 feet (1,370 m).
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS
Manifold Press: (w.c.)
Maximum Supply Pressure
Minimum Supply Pressure
Model Number
Max. BTU/hr Input
BEFORE YOU START
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents
for shipping damage and immediately inform your dealer if any damage is found. Do not install any
unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed
parts have been received.
ITEMS REQUIRED FOR INSTALLATION
Tools:
• Phillips screwdriver
• Hammer
• Saw and/or saber saw
• Level
• Measuring tape
• Electric drill and bits
• Pliers
• Square
• Pipe Wrench
6
PROPANE GAS
3.5"
Manifold Press: (w.c.)
7"
Maximum Supply Pressure
4.5"
Minimum Supply Pressure
B-Vent Specialty
Natural
42,000
Building Supplies:
• Framing materials
• Wall finishing materials
• Caulking material (noncombustible)
• Fireplace surround material (noncombustible)
• Piping complying with Local Codes
• Tee joint
• Pipe sealant approved for use with Propane/LP gas
(resistant to sulfur compounds)

PRE-INSTALLATION INFORMATION

10"
13"
11"
Propane
42,000
53D9009