MHSC B-Vent 400BBVPV Installation & Operating Instructions Manual

B-vent series natural vent gas fireplace
Hide thumbs Also See for B-Vent 400BBVPV:
Table of Contents

Advertisement

Models:
400BBVNV/PV/NE/PE/NSC/PSC,
400SBVNV/PV/NE/PE/NSC/PSC,
500SBVNV/PV/NE/PE/NSC/PSC
WARNING
IF THE INFORMATION IN THESE INSTRUCTIONS IS
NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF LIFE.
— Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. Refer to this man-
ual. For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
B-Vent Series
Natural Vent Gas Fireplace
Installation & Operating
4037
BBV SBV cover
Instructions
9/08
DUE TO HIGH TEMPERATURES, THE APPLI-
ANCE SHOULD BE LOCATED OUT OF TRAF-
FIC AND AWAY FROM FURNITURE AND DRAP-
ERIES.
CHILDREN AND ADULTS SHOULD BE ALERT-
ED TO THE HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS THE
APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATE-
RIAL SHOULD NOT BE PLACED ON OR NEAR
THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND FREE
FROM COMBUSTIBLE MATERIALS, GASO-
LINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-
ence.
62D4037 8/10 Rev. 14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B-Vent 400BBVPV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MHSC B-Vent 400BBVPV

  • Page 1 B-Vent Series Natural Vent Gas Fireplace Models: 400BBVNV/PV/NE/PE/NSC/PSC, 400SBVNV/PV/NE/PE/NSC/PSC, 500SBVNV/PV/NE/PE/NSC/PSC WARNING Installation & Operating 4037 IF THE INFORMATION IN THESE INSTRUCTIONS IS BBV SBV cover Instructions NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION 9/08 MAY RESULT CAUSING PROPERTY DAMAGE, PER- SONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS BBV, SBV Series Natural Vent Gas Fireplaces Thank you and congratulations on your purchase of an MHSC Fireplace Please read the Installation and Operation Instructions before using the appliance! IMPORTANT: Read all instructions and warnings carefully before starting installation.
  • Page 3: Important Safety Information

    BBV, SBV Series Natural Vent Gas Fireplaces IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4: Code Approval

    BBV, SBV Series Natural Vent Gas Fireplaces IMPORTANT SAFETY INFORMATION Continued on Page 4 14. Do not use any solid fuels (wood, coal, paper, card- IMPORTANT: board, etc.) in this fireplace. Use only the gas type indicated on rating plate. PLEASE READ THE FOLLOWING CAREFULLY 15.
  • Page 5: Product Specifications

    BTU/h Size natural or propane gas. See appropriate data plates. 400BBVNV Nat. 22,000 16,000 • This appliance is not for use with solid fuels. 400BBVPV 22,000 16,000 • The appliance must be installed in accordance with 400BBVNE Nat. 22,000 16,000 local codes if any.
  • Page 6: Fireplace And Framing Dimensions

    BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE & FRAMING DIMENSIONS FIREPLACE FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figures 2 or 3 for your specific installation requirements. Refer to Figures 2 & 3 for firebox dimensions.
  • Page 7 BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE & FRAMING DIMENSIONS Min. Rough  Opening 6”  Depth B-Vent 21” (533 mm) 21 ” ” (546 mm) 1/2” or 5/8” (341 mm) 6 ” Drywall  (165 mm) Spacers D - Min. Rough Opening Width Min. Rough Opening  Height 38" 38 ” 1/2" or 5/8"  (965 mm) (978 mm) Drywall  34”...
  • Page 8: Fireplace Location

    BBV, SBV Series Natural Vent Gas Fireplaces PRE-INSTALLATION INFORMATION FIREPLACE LOCATION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional acces- sories (i.e.
  • Page 9: Secure Fireplace

    BBV, SBV Series Natural Vent Gas Fireplaces SECURE FIREPLACE TO FLOOR OR FRAMING The fireplace must be secured to the floor and/or to framing studs Framing as shown in Figure 5. Use two (2) wood screws or masonry/con- crete screws to secure fireplace 1/2”...
  • Page 10: Venting Installation

    Attach the strap toward the • Installation of any component part not manufac- bottom of the flue section and pull taut for proper tured or approved by MHSC. tension to the firebox. • Installation other than permitted by these instruc- Attaching 6”...
  • Page 11: Firestops

    VENTING INSTALLATION BBV, SBV Series Natural Vent Gas Fireplaces FIRESTOPS • NOTICE: When installing in a chase, you should insu- Locate chimney centerline dimension from a com- late the chase as you would the outside walls of your bustible back wall. Figures 2 & 3. Minimum firestop home.
  • Page 12: Outside Combustion Air

    BBV, SBV Series Natural Vent Gas Fireplaces OUTSIDE COMBUSTION AIR NOTE: The use of outside air for combus- tion is optional unless required by building codes. It is only necessary to supply outside combustion air to one side of fireplace. Use model OAC4 combustion air kit (refer to Page 17).
  • Page 13: Combustion Air Assembly

    BBV, SBV Series Natural Vent Gas Fireplaces COMBUSTION AIR ASSEMBLY MODEL OAC-4 COMBUSTION AIR ASSEM- DO NOT remove the cover if the outside air will not be connected. 1. Remove the cover plate from the 4” outlet opening location on the left outside of the fireplace. 2.
  • Page 14: Fireplace Installation

    BBV, SBV Series Natural Vent Gas Fireplaces FIREPLACE INSTALLATION CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas types, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type.
  • Page 15 FIREPLACE INSTALLATION BBV, SBV Series Natural Vent Gas Fireplaces A manual shut-off valve must be installed Only persons licensed to work with gas upstream of the appliance. Union tee and piping may make the necessary gas plugged 1/8” NPT pressure tapping point connections to this appliance.
  • Page 16: Check Gas Pressure - Millivolt

    BBV, SBV Series Natural Vent Gas Fireplaces CHECK GAS PRESSURE & ELECTRICAL INSTALLATION - MILLIVOLT 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas sup- ply is different from the fireplace, STOP! Do not install the appliance.
  • Page 17: Electrical Installation

    ELECTRICAL INSTALLATION BBV, SBV Series Natural Vent Gas Fireplaces REMOTE WALL MOUNTED SWITCH A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 18. Do not extend beyond the wall switch wire length provided.
  • Page 18: Electronic Pilot Ignition Wiring

    ELECTRICAL INSTALLATION BBV, SBV Series Natural Vent Gas Fireplaces ELECTRONIC PILOT IGNITION WIRING Do not connect 110-120V AC to the Re- mote Wall Switch. The appliance will malfunction or destroyed. Figure 19 - FP2027 Electronic Ignition System Wiring Diagram REMOTE WALL SWITCH Position the wall switch.
  • Page 19: Operating Instructions - Millivolt

    OPERATING INSTRUCTIONS - MILLIVOLT BBV, SBV Series Natural Vent Gas Fireplaces FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in- jury or loss of life. A.
  • Page 20: Lighting Pilot

    BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS - MILLIVOLT LIGHTING PILOT FOR THE FIRST TIME APPROVED LEAK TESTING METHOD If using a soap and water solu- You may check for gas leaks with the following methods only: tion to test for leaks, DO NOT •...
  • Page 21: Lighting Burner

    BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS - MILLIVOLT LIGHTING BURNER MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found behind the door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 22: Operating Instructions - Electronic Ignition

    BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS - ELECTRONIC IGNITION FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal in- jury or loss of life. A.
  • Page 23: Check Gas Pressure - Signature Command System

    SIGNATURE COMMAND - CHECK GAS PRESSURE and ELECTRICAL INSTALLATION BBV, SBV Series Natural Vent Gas Fireplaces 1. Check gas type. The gas supply must be the same as Pressure Inlet stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance.
  • Page 24: Junction Box Wiring

    BBV, SBV Series Natural Vent Gas Fireplaces SIGNATURE COMMAND - ELECTRICAL INSTALLATION JUNCTION BOX WIRING 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with mini- mum 60° C wire in accordance with prevailing codes. 2.
  • Page 25: Scs Wiring Diagram

    BBV, SBV Series Natural Vent Gas Fireplaces ELECTRICAL INSTALLATION Pilot RF Receiver ON/OFF Button Control Board 6V AC Black / Thermopile Adapter Red / Thermopile Sensor Conversion NG/LP Spill Switch Ignitor / Sparker Plug-in Connector Control Board to Command Center OFF/LO ON/HI Master Switch Plug-in Connector NOTE: Wall switch wires must be con- Command Center Optional Stepper Motor to nected together if a wall switch is not Control Board Wall Switch Ground...
  • Page 26: Operating Instructions - Scs

    BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS - SIGNATURE COMMAND FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A.
  • Page 27: Operating Instructions

    BBV, SBV Series Natural Vent Gas Fireplaces OPERATING INSTRUCTIONS - SIGNATURE COMMAND OPERATING INSTRUCTIONS 1. STOP! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 28: Signature Command System Operation Instructions

    BBV, SBV Series Natural Vent Gas Fireplaces SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS To Thermopile RF Receiver FEATURES ON/OFF To Sensor Command Center To Sparker • Easy Access Function Operation and System Configuration NG/LP • Operation Confirmation/Fault Diagnostic Indications (LED/ Conversion Buzzer) •...
  • Page 29: System Configuration/Setup

    BBV, SBV Series Natural Vent Gas Fireplaces SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS SYSTEM CONFIGURATION/SETUP All System configuration/setup is done on the Command Center. NOTE: When using On/Off wall switch, the switch must be in the ON position to perform all configuration set ups at the command center.
  • Page 30: Signature Command System Operation Instructions

    BBV, SBV Series Natural Vent Gas Fireplaces SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS FUNCTIONS/OPERATION Turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center or turn on wall switch. Pilot will light and burner will come on High setting or last memory setting (See Turning Off Fireplace below).
  • Page 31: Final Installation

    FINAL INSTALLATION BBV, SBV Series Natural Vent Gas Fireplaces ROCK WOOL PLACEMENT Cover with 1. Place rock wool on burner to provide glowing Rock Wool embers. For best results, pull the rock wool apart into pieces the size of a nickel or dime. Burner 2.
  • Page 32: Cleaning And Maintenance

    BBV, SBV Series Natural Vent Gas Fireplaces CLEANING and MAINTENANCE Thermocouple Turn off gas before servicing fireplace. It Thermopile is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMPART- MENT Keep the control compartment, logs and burner areas Millivolt Pilot...
  • Page 33: Vent System

    CLEANING and MAINTENANCE BBV, SBV Series Natural Vent Gas Fireplaces VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a quali- fied field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 34: Troubleshooting

    BBV, SBV Series Natural Vent Gas Fireplaces TROUBLESHOOTING STANDING PILOT IGNITION SYMPTOM POSSIBLE CAUSE ACTION 1. Spark igniter A. Wire disonnected. A. Open door and check to make sure wire is connected to will not light pi- igniter. lot after repeat- B.
  • Page 35: Electronic Ignition

    TROUBLESHOOTING BBV, SBV Series Natural Vent Gas Fireplaces ELECTRONIC IGNITION START 1. Turn gas supply off. Check: Line voltage (120VAC) 2. Turn ON/OFF switch to “ON” Low voltage transformer (19.5 minimum VAC) Power to module (24V Normal) ON/OFF switch Wiring connections Is there a spark across Unplug ignition lead and ignitor sensor gap?
  • Page 36 BBV, SBV Series Natural Vent Gas Fireplaces TROUBLESHOOTING GENERAL TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION 1. Glass soots. A. Flame impingement on A. Install log set per instructions. logs. Inspect the injector and air intake area. Make sure this area does not have any blockage from debris and clean.
  • Page 37 TROUBLESHOOTING BBV, SBV Series Natural Vent Gas Fireplaces SIGNATURE COMMAND SYSTEM ACTION  OPERATION  FAULT  DIAGNOSIS  Using  Battery polarity wrong?  Re-install batteries  battery?  Make sure  Command  Install batteries and/or  Battery voltage low?  Change batteries  Center and  plug in the AC board  A  No beep in about  the control  8 seconds  board are  connected by  a 2 feet or 15  AC plug is plugged to  Plug the AC plug to   feet cable  AC mains?  AC mains  Flip the master switch  The 5-pin connector on  Repair or replace the  ...
  • Page 38: Replacement Parts

    BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS FIREBOX COMPONENTS 1  6  2  4a  4b  4c  3  5  7  62D4037 624037 BBV SBV firebox parts...
  • Page 39: Logs

    REPLACEMENT PARTS BBV, SBV Series Natural Vent Gas Fireplaces FIREBOX COMPONENTS Item Description Qty. 400BBV 400SBV 500SBV Pull Screen Panel 61D0001 61D0001 61D0003 Refractory Side 61D0101 61D0101 Refractory Back 61D0102 61D0102 Left Refractory 62D1015 62D2015 Middle Refractory 62D1016 62D2016 Right Refractory 62D1017 62D2017 Optional Field Installed Accessoriesd...
  • Page 40: Standing Pilot - Millivolt Control

    BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL 12, 13 62D4037...
  • Page 41 BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL Item Description Qty. 400BBVNV 400BBVPV 400SBVNV 400SBVPV 500SBVNV 500SBVPV Gas Valve Assembly 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 Pilot Assembly 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019...
  • Page 42: Electronic Ignition

    BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS ELECTRONIC IGNITION 62D4037...
  • Page 43 REPLACEMENT PARTS BBV, SBV Series Natural Vent Gas Fireplaces ELECTRONIC IGNITION Item Description Qty. 400BBVNV 400BBVPV 400SBVNV 400SBVPV 500SBVNV 500SBVPV Gas Valve Assembly 37D0016 37D0017 37D0016 37D0017 37D0016 37D0017 Pilot Assembly 37D0020 37D0021 37D0020 37D0021 37D0020 37D0021 Burner Tube 62D4051...
  • Page 44: Signature Command System

    BBV, SBV Series Natural Vent Gas Fireplaces REPLACEMENT PARTS SIGNATURE COMMAND SYSTEM 14,15 624037 BBV/SBV Signature command parts 62D4037...
  • Page 45 REPLACEMENT PARTS BBV, SBV Series Natural Vent Gas Fireplaces SIGNATURE COMMAND SYSTEM Item Description Qty. 400BBVN 400BBVP 400SBVN 400SBVP 500SBVN 500SBVP Gas Valve Assy 80D0001 80D0002 80D0001 80D0002 80D0001 80D0002 Pilot Assy 80D0006 80D0007 80D0006 80D0007 80D0006 80D0007 Control Box 80D0018 80D0019 80D0018...
  • Page 46: For Massachusetts Residents Only

    Massachusetts Residents Only — Please read and follow these special requirements BBV, SBV Series Natural Vent Gas Fireplaces 2. Approved Carbon Monoxide Detectors. Each carbon NOTE REGARDING VENTED PRODUCTS monoxide detector as required in accordance with the above This product must be installed by a licensed plumber or gas fitter provisions shall comply with NFPA 720 and be ANSI/UL 2034 when installed within the Commonwealth of Massachusetts.
  • Page 47: Warranty

    (2) years from date of installation. After installation, if any of the components manufactured by MHSC in the appliance are found to be defective in materials or workmanship, MHSC will, at its option, replace or repair the defective components at no charge to the original owner.
  • Page 48 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com...

Table of Contents