B-Vent Specialty Gas Fireplaces
NOTE: The use of outside air for combus-
tion is optional unless required by build-
ing codes. It is only necessary to supply
outside combustion air to one side of fire-
place. Use model OAC4 combustion air kit
(refer to Page 17).
1. Avoid extremely long runs and numer-
ous turns in duct leading from fireplace
to combustion air assembly. These condi-
tions increase the resistance to free flow
of air through duct. Figures 12 and 13
2. Locate combustion air assembly at an
exterior location. Make sure the location
cannot be accidentally blocked. Locate
assembly above snow line to prevent
snow from blocking assembly.
3. Never mount combustion air inlet assem-
bly in garage or storage area where com-
bustible fumes (gasoline) might be drawn
into fireplace.
4. Combustion air may be drawn from crawl
space under house when adequate sup-
ply of air is provided by open ventilation.
Figure 12
NOTE: Never take combustion air from at-
tic space or garage space.
NOTE: Install outside combustion air
ONLY ON LEFT-HAND SIDE of fireplace.
16

OUTSIDE COMBUSTION AIR PRECAUTIONS and RECOMMENDATIONS

Figure 13
Duct Extended
to Miss Joist
Installed above Basement or
Crawl Space
Figure 12
Inlet Grille
8"
in Soffit
Maximum
(Overhang)
Installed on Concrete Slap
FP2210
53D9009