DISPLAY BACKLIGHT
Press the
The backlight will automatically turn off after 15 seconds.
BATTERY CHECK
The
CHECK function tests the condition of the 9V battery.
Set the function switch to the 200VDC range and press the
CHECK button. If the reading is less than 8.5, battery
replacement is recommended.
DATA HOLD
The hold function freezes the reading in the display. Press the
HOLD key momentarily to activate or to exit the hold function.
AUTO POWER OFF
The auto off feature will turn the meter off after 15 minutes.
LOW BATTERY INDICATION
If the
icon appears in the display when the battery voltage is
low. Replace the battery when this icon appears.
WRONG CONNECTION INDICATION
The
icon will appear in the upper right corner of the display
and the buzzer will sound whenever the positive test lead is
inserted into the 20A or uA/mA input jack and a non-current
(yellow) function is selected. If this occurs, turn the meter off and
reinsert the test lead into the proper input jack for the function
selected.
button to turn on the display backlight function.