3100-I ACC Wood Insert
E. Glass Cleaning
Frequency: As desired
By: Homeowner
Clean glass with a non-abrasive glass cleaner. Abrasive
cleaners may scratch and cause glass to crack.
If the deposits on the glass are not very heavy, normal
glass cleaners work well. Heavier deposits may be
removed by using a damp cloth dipped in wood ashes or
by using a commercially available oven cleaner.
After using an oven cleaner, it is advisable to remove any
residue with a glass cleaner or soap and water. Oven
cleaner left on during the next fi ring can permanently
stain the glass and damage the fi nish on plated metal
surfaces.
• A portion of the combustion air entering the fi rebox is de-
fl ected down over the inside of the door glass.
• This air fl ow "washes" the glass, helping to keep smoke
from adhering to its surface.
• When operated at a low burn rate, less air will be fl owing
over the glass and the smoky, relatively cool condition of
a low fi re will cause the glass to become coated.
Operating the appliance with the Burn Rate Air Control
and Start-Up Air Control all the way open for 15-20 min-
utes should remove the built up coating.
CAUTION! Handle glass assembly with care. Glass is
.
breakable
Avoid striking, scratching or slamming glass
Avoid abrasive cleaners
Do not clean glass while it is hot
Figure 18.1
Page 18
F. Inspect Firebrick
Frequency: After each ash removal
By: Homeowner
Replace the fi rebrick if they become crumbly and/or if
there is a 1/4 inch (6.35mm) gap between the bricks.
The fi rebox is lined with fi rebrick, which has exceptional
insulating properties. Do not use a grate; simply build
a fi re on the fi rebox fl oor. Do not operate appliance
without fi rebrick.
1. After the coals have completely cooled, remove all
old brick and ash from unit and vacuum fi rebox.
2. Remove new brick set from box and lay out to
diagram shown.
3. Lay bottom bricks in unit.
4. Install rear bricks on the top of the bottom bricks.
Slide top of bricks under clip on back of fi rebox wall
and push bottom of bricks back.
5. Install side bricks. Slide top of brick under clips
on side of fi rebox and push the bottom of the brick
until it is fl ush with the side of the unit.
Use Part 832-0550 when ordering individual brick. Provide
brick dimension or copy this page, mark the desired brick and
take it to your authorized dealer.
1
1
1
4
2
Figure 18.2
No.
1
9 x 4-1/2 x 1-1/4
2
6 x 4-1/2
3
9 x 4-1/2 w/angle
4
9 x 3 w/angle
7044-140C
1
1
1
1
1
1
2
2
2
Brick Size
November 21, 2011
R
1
1
1
3
Qty
12
4
1
1

Advertisement

Table of Contents
loading

Table of Contents