FIGURE 3: SUGGESTED LAYOUT FOR COMFORT
X
TABLE 2: SUGGESTED LAYOUT / MOUNTING DISTANCES FOR COMFORT*
SUSPENDED HORIZONTALLY: (long axis level)
MODEL
ecoSchwank-X 36 - IL-X 150
ecoSchwank-X 52 - IL-X 200
SUSPENDED AT AN ANGLE 30° ON SHORT AXIS: (long axis level)
MODEL
ecoSchwank-X 36 - IL-X 150
ecoSchwank-X 52 - IL-X 200
* The Mounting distances are suggested, and may vary depending on insulation/heat loss val-
ues, air movement/change, and other site conditions and comfort requirements. If in doubt,
please contact Schwank Design Services.
For 'spot' heating, the distance above the floor can be reduced by 4 to 6 feet (61 to 132 cm)
depending upon site conditions.

SP-MECX-EX-5A

ECO-X 36-52 / IL-X 150-200 Manual
RD: MAY 2009
RL: 05A - BA
X
Z
TYPICAL
ABOVE
FLOOR
< X >
28' (850 cm)
30' (915 cm)
TYPICAL
ABOVE
FLOOR
< X >
26' (800 cm)
28' (850 cm)
Y
Long axis always level
TYPICAL
BETWEEN
HEATERS
< Y >
45' (1375 cm)
50' (1525 cm)
TYPICAL
BETWEEN
HEATERS
< Y >
45' (1375 cm)
50' (1525 cm)
12
Z
Short axis may
rotate up to 30°
X
TYPICAL
BETWEEN
ROWS
< Z >
85' (2600 cm)
90' (2750 cm)
TYPICAL
BETWEEN
ROWS
< Z >
100' (3050 cm)
100' (3050 cm)