Wiring the Wall Switch
Once a location is chosen and the electrical box is installed
proceed as follows. Install the provided control wire from the
fi replace to the switch location. (Control wire for Heatilator
products is supplied with the fi replace). Use caution not to
stress the wire around tight or sharp corners. Do not run the
control wire adjacent to existing or future phone, data, cable,
or electrical lines. The wire should not come into contact with
any part of the fi replace exterior with the exception of where
it exits the outer wrap. Feed the wire to the electrical junction
box and through a provided or approved strain relief. Us-
ing a screw driver, connect the red wire to the "R" terminal,
the yellow or white wire to the "W" or "Y" terminal, and the
green wire to the "G" terminal. Do not over-tighten. Using
the screws provided, mount the switch to the electrical junc-
tion box right side up. Install provided cover plate using the
screws provided. Do not use a substitute cover even though
it may fi t. The provided one is specifi cally designed for the
automatic (thermostat) function of the unit.
ORANGE
GROUND
BLACK
IPI
VALVE
FLAME
SOLENOID
ADAPTER WIRES
* May be labeled as "W" or "Y".
Figure 10.2 Intellifi re (IPI) Wiring Diagram
46
BLACK
WHITE
BROWN
GREEN
1
2
IPI
3
MODULE
4
5
6
7
8
RED
FLAME ON
RED
FLAME HIGH/LOW
AC
PLUG
AUX
CONNECTION
Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
BATTERIES
BLACK
RED
YELLOW OR
WHITE
BROWN
BROWN
RED
3V DC
BLACK
ORANGE
ORANGE
BLACK
BLACK
GROUND PIGTAIL
GREEN
CAUTION
RED
REAR VIEW
GREEN
*
*
FRONT VIEW
YELLOW
YELLOW
SENSOR SWITCH
FAN THERMOSTAT
BLACK
TEMPERATURE
FAN
CONNECTION