Heatilator CNXT4236IT Owner's Manual page 35

Direct vent gas appliance
Hide thumbs Also See for CNXT4236IT:
Table of Contents

Advertisement

Assemble Pipe Sections
Insert the inner fl ue of section A into the fl ared inner fl ue of
section B.
Start the outer fl ue of section A over the outer fl ue of section
B (see Figure 8.2).
Once both inner and outer fl ues are started, press section
A onto section B fi rmly until all lances have snapped into
place. Check to make sure they have snapped together (see
Figure 8.3) and the seams are not aligned (see Figure 8.4).
Tug slightly on section A to confi rm it has completely locked
into place. It is acceptable to use screws no longer than 1
in. (25 mm) to hold outer pipe sections together. If predrilling
holes, do NOT penetrate inner pipe
For 90° and 45° elbows that are changing the vent direction
from horizontal to vertical, one screw minimum should be
put in the outer fl ue at the horizontal elbow joint to prevent
the elbow from rotating. Use screws no longer than 1 in. (25
mm). If predrilling holes, do NOT penetrate inner pipe.
Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07
High Temperature Silicone Sealant
Commercial, Multi-family (multi-level exceeding two
stories), or High-rise Applications only
Figure 8.1
Lances
A
B
Figure 8.2
Inner/Outer
Make sure the seams are not aligned to prevent unintentional
disconnection.
CORRECT
Figure 8.4
Seams
A
B
Figure 8.3
Snapped
INCORRECT
35