4. Squeeze the open end of the bent baffl e with one hand.
Insert the baffl e bent side up into the inner fl ue so that
the bottom of the baffl e is above the bead on the inside
of the collar. See Figure 5.22.
Figure 5.22 Placing the Baffl e
5. Release pressure on the baffl e so that it is wedged against
the sides of the fl ue collar. See Figure 5.23.
Figure 5.23 Baffl e in Place
6. Reinstall refractory in reverse order of removal (see
#3).
7. Replace the glass (refer to Section 12.H.).
8. Start the appliance.
Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07