Framing And Clearances; Select Appliance Location - Heatilator CNXT4236IT Owner's Manual

Direct vent gas appliance
Hide thumbs Also See for CNXT4236IT:
Table of Contents

Advertisement

3 3

Framing and Clearances

Note:
Illustrations refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
A. Select Appliance Location
When selecting a location for your appliance it is important to
consider the required clearances to walls (See Figure 3.1).
1/2 in. (13 mm) min.
appliance to
combustibles
B
F
1 in. (25 mm) min.
pipe to combustibles
Model #
CNXT4236
CNXT4842
Figure 3.1
Appliance Locations
B
Drywall
D
A
Top Vent
One 90° elbow
Horiz Term
In addition to these framing dimensions, also reference the
following sections:
• Clearances and Mantel Projections (Section 3.C.)
• Vent Clearances and Framing (Section 6)
Rear Vent
One 90° elbow
Vert Term
A
F
A
B
in.
42
50-5/8
23-1/2
mm
1067
1286
597
in.
48
55-1/4
23-1/2
mm
1219
1403
597
Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07
Fire Risk
Provide adequate clearance:
Locate appliance away from traffi c areas.
Note: For actual applianc e dimensions refer to
Section 16.
C
A
H
G
Alcove
Installation
No elbows
Horiz Term
Two 90° elbows
A
Horiz Term
C
C
D
E
F
71-5/8
50-5/8
52-5/8
1819
1286
1337
78-1/4
55-1/4
55-1/4
1988
1403
1403
WARNING
Around air openings.
For service access.
E
1/2 in. (13 mm) min.
appliance to
combustibles
A
Rear vent
One 45° elbow
Horiz Term
Rear Vent
A
I
G
H
I
43
48
59-3/4
1092
1220
1518
49
48
59-3/4
1245
1220
1518
1 in. (25 mm) min.
pipe to
combustibles
E
I
7

Hide quick links: