Remote Models - Manitowoc S Service Manual

S model
Table of Contents

Advertisement

Section 6

REMOTE MODELS

Initial Start-Up Or Start-Up After
Automatic Shut-Off
1. WATER PURGE
Before the compressor starts, the
water pump and water dump
solenoid are energized for 45
seconds to purge old water from the
ice machine. This ensures that the
ice-making cycle starts with fresh
water.
NOTE: The harvest valve and
harvest pressure regulating (HPR)
solenoid valve are also energized
during the water purge. In the case of
an initial refrigeration start-up or auto
shut-off, they stay on for an additional
5 seconds (50 seconds total).
Table 6-8. Remote Models
Toggle Switch
Bin Switch
Control Board Relays
#1
Water Pump
#2
Harvest Valve (Left) / HPR Valve
#3
Harvest Valve (Right)
#4
Air Compressor
#5
Water Inlet Valve
#6
Water Dump Valve
#7
Contactor Coil / Liquid Line Solenoid
#7A
Compressor
#7B
Condenser Fan Motor
Safety Controls (Which could stop ice machine operation)
High Pressure Cut-Out
Main Fuse (On Control Board)
Part Number 80-1480-3
(L1)
Ground
(89)
(55)
High Pressure
Cut-out
(88)
(42)
Ice Thickness
Probe
Water Level
Probe
Compressor
Contactor
Contacts
Black
(L1)
(51)
Remote - Water Purge
1. Water Purge (45 Seconds)
(20)
(61)
Control Board
(2)
(60)
(6)
(5)
(1)
(7)
(57)
(4)
Trans
(58)
Fuse 7A
L2
(56)
(25)
(26)
Air Compressor
(9)
(8)
Bin Switch
Low DC
(6)
Voltage
Plug
Clean
(1)
OFF
(2)
ON
Red
Yellow
(46)
PTCR
(F1)
Remote Fan Motor
Run Capacitor
Electrical System
Water Valve
(21)
(22)
(L2)
(82)
HPR Valve
(78)
(79)
(77)
(80)
Harvest Valve
(76)
(81)
Dump Valve
(99)
(98)
Water Pump
(83)
(22)
Liquid Line
(59)
(75)
Solenoid
Contactor Coil
(74)
Run
Cap.
(50)
(45)
(F2)
Remote
Condenser
SV3158-1
ICE
Closed
ON
ON
ON (When Used)
35 sec. OFF / 10 sec. ON
OFF
ON
Open / OFF
OFF
OFF
Closed
Closed
6-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents