Manitowoc SN12 Replacement Instructions

Nugget ice machines cutter head

Advertisement

Manitowoc SN12/SN20 Model Nugget Ice Machines
1. Disconnect water supply.
2. Remove front panel.
3. Move toggle switch to CLEAN position after the 5 minute delay expires. The evaporator and float
chamber will drain.
4. Disconnect power at electrical disconnect.
Disconnect power to the ice machine at the electrical disconnect, moving
the toggle switch to the off position will not disconnect line voltage.
5. Remove top, left and right side panels.
6. Remove ice chute assembly.
NOTE; if the ice wiper can not be hand removed; place the handle end of a screwdriver against the ice
wiper, then tap the screwdriver (counterclockwise) with a hammer to loosen the ice wiper from the
auger.
Manitowoc Foodservice
th
2110 South 26
Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879
Web Site -
www.manitowocice.com
Cutter Head Replacement Instructions
WARNING
REMOVE COVER
REMOVE ICE DAMPER
REMOVE STRAINER
REMOVE ICE WIPER
REMOVE ICE CHUTE
LOOSEN HOSE CLAMP AND
DISCONNECT DRAIN LINE
000004021
Sheet 1 of 2
08/25/08

Advertisement

loading

Summary of Contents for Manitowoc SN12

  • Page 1 Manitowoc SN12/SN20 Model Nugget Ice Machines 1. Disconnect water supply. 2. Remove front panel. 3. Move toggle switch to CLEAN position after the 5 minute delay expires. The evaporator and float chamber will drain. 4. Disconnect power at electrical disconnect.
  • Page 2 7. Peel evaporator insulation down to expose Use puller to remove cutter head from auger shaft. NOTE: If the bearing is destroyed or the auger heavily damaged from bearing wear contact the Manitowoc service department @ 1-800-545-5720. 8. Install new cutter head and secure with three bolts removed in step 7. Use removable loctite on bolt threads.

This manual is also suitable for:

Sn20