Heat & Glo SL-550METRO-LP Owner's Manual page 27

Fireplace
Hide thumbs Also See for SL-550METRO-LP:
Table of Contents

Advertisement

H
+ H
1
V
Minimum
1
SL-550METRO
1 ft.
305 mm
6 ft.
1-1/2 ft.
457 mm
10 ft.
2-1/2 ft.
762 mm
12 ft.
3-1/2 ft.
1.1 m
14 ft.
H
1
V
+ V
1
2
*No specifi c restrictions on this value EXCEPT V
Figure 7.6
Top Vent - Horizontal Termination
Venting with three 90º elbows
Maximum
2
V
2
1.8 m
*
3.0 m
*
3.7 m
*
4.3 m
*
+ H
MAX. = 14 ft. (4.6 m)
2
+ H
+ H
MAX. = 40 ft. (12.2 m)
1
2
+ V
+ H cannot exceed 40 ft. (12.2 m)
1
2
H
2
WARNING
Fire Risk.
• A one foot minimum vertical
vent section is required before
installing fi rst elbow.
Heat & Glo • SL-550METRO, SL-550METRO-LP • 2185-900 Rev. D • 8/09
V1 + V2 Min.
*
*
*
*
V
2
H
1
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when using
fl ex vent except when using the
simple up and out installation
(see Figure 7.3).
V
1
27