Flueing Information A. Chimney And Exhaust Connection; Outside Air Kit Instructions - Heatilator ECO-NZ-PS35 Owner's Manual

Pellet burning stove
Hide thumbs Also See for ECO-NZ-PS35:
Table of Contents

Advertisement

7
Flueing Information
A. Chimney and Exhaust Connection
The flue must be installed by a suitably qualified person in
accordance with AS/NZS2918:2001 and the manufactures
instructions. The ECO-CHOICE pellet fire range use a fan
powered exhaust system with a slightly negative pressure
in the combustion chamber and a slightly positive pressure
in the flue.
Flue parts need to be
1. Combustion and condensation proof (stainless
steel)
2. Have no restrictions or draft adjustment devices
3. Must be suitably insulated where they are outside
the room the fire is located
4. Have the correct clearances from combustible
materials
5. Free standing models must have a T adapter /
cleanout at the connection to the fire.
6. INSTALL FLUE AT CLEARANCES SPECIFIED BY
THE FLUE MANUFACTURER.
7. Secure flue system to the appliance with at least
three (3) screws/rivets per the pipe manufacturer's
instructions. Also secure all connector pipe joints
with at least three (3) screws/rivets through each
joint.
8. DO NOT INSTALL A FLUE DAMPER IN THE
EXHAUST VENTING SYSTEM OF THIS UNIT.
9. DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING ANOTHER APPLIANCE.
Switch recommends the use of Davin flu kits as outlined on
page 28 and page 29. These have been tested and
approved for use with the ECO-CHOICE range of fires if
you intend to use a different flue kit you will need to consult
with your local council
NOTE: Seal pipe joints with high temperature silicone , or
equivalent, (250°C minimum rated only). Do not put sealant
inside of pipe.
Vent surfaces get HOT, can cause burns if
touched. Non-combustible shielding or guards
may be required.
www.heatilatorecochoice.com
WARNING
Heatilator • ECO-NZ-PS35 • 7072-111B • December 1, 2011
NOTE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual
design preference.
B. Outside Air Kit Instructions
There are two Outside Air Kits that will work with this
appliance. One kit, 811-0872 uses a 2 inch flex hose
(included) and uses hose clamps to secure the hose. The
other kit, OAK-3, uses a 3 inch flex hose (not included) and
uses wire ties to secure the hose.
Parts Included in 2 inch Kit 811-0872: 1 piece of 2
inch x 3 ft. flex hose, 2 hose clamps, 1 collar assembly, 1
termination cap assembly, trim ring, 1 intake air channel,
fasteners (Discard the air intake channel, it is not needed for
this appliance.
2 Inch Outside Air Kit Shown
Collar Assembly
Hose Clamp
Figure 35 2 Inch Outside
Air Kit Shown
Air Intake Channel
(Discard)
Figure 36
CAUTION
Never draw
outside
combustion air
from:
• Wall, floor or
ceiling cavity
• Enclosed space
such as an attic,
garage or crawl
space.
2 inch flex hose
Trim Ring
Hose Clamp
Termination Cap