ENV06 EWM11xx EWM21xx EWM25xx/35xx
3 ENV 06
3.1 Access to the diagnostic cycle
3.1.1
All version
1. Switch off the appliance.
2. Press and hold down the START/PAUSE button and the nearest OPTION button
simultaneously (as represented in figure).
3. Holding down both buttons, switch the appliance on by turning the programme selector one
position clockwise.
4. Continue to hold down the buttons until the LEDs begin to flash (at least 2 seconds).
5. To exit the diagnostic system, switch off, switch on and switch off again the appliance.
3.1.2
INPUT version
1. Switch off the appliance.
2. Press and hold down START/PAUSE button and the nearest option button (as represented in
figure).
3. Holding down both buttons, switch the appliance on pushing button ON/OFF.
4. The test of the display board starts immediately.
5. To exit the diagnostic system, switch off, switch on and switch off again the appliance.
3.1.3
Rapid reading of alarm codes
The last three alarm codes can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
→ Press and hold down START/PAUSE and the nearest option button (as to enter the
DIAGNOSTICS), for at least two seconds: the LEDs initially switch off, and then display the flashing
sequence indicating the last alarm.
→ To display the previous alarms press the left button of the START/PAUSE button sequentially.
→ To return to the last alarm, press the START/PAUSE button.
→ The alarm sequence continues as long as the two buttons are held down.
→ While the alarms are displayed, the appliance continues to perform the cycle or, if in the programme
selection phase, maintains the previously-selected options in memory.
QUICK GUIDE AND APPLIANCES LIST
41/176
599 72 40-80