EWM1000plus EWM2000evo EWM3000new
2.5 DELTA Version without selector and button ON/OFF switch
2.5.1
Access to diagnostics system
1. Reset the set programme with the SKIP/RESET button and then switch the appliance off.
2. Press the START/PAUSE and SKIP/RESET buttons simultaneously and then, holding the
buttons down, switch the appliance on using the ON/OFF button.
3. Hold the buttons down until the buzzer sounds and the LEDs start flashing (about 4 seconds).
4. To exit the diagnostics system switch the appliance off, on and then off again.
2.5.2
Rapid reading of alarm codes
The last alarm code can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
Press START/PAUSE and SKIP/RESET buttons simultaneously for at least 2 seconds: the LEDs switch
off and then display the sequence of flashes indicating the alarm.
The alarm sequence is displayed for the time in which the buttons are hold down
During the time the alarm is displayed, the appliance continues to perform the cycle or, if it is in the
selection phase, it keeps the options previously chosen in memory.
2.5.3
Cancelling the last alarm
It is good practice to cancel the last alarm, after reading the alarm code to check whether the alarm re-
occurs during the diagnostics control after the reparation of the appliance
1. Select diagnostics mode and Press the Fabrics (1) or Temperature (2) button until LED L10
lights (reading of alarm).
2. Press and hold down START/PAUSE and START/RESET.
QUICK GUIDE AND APPLIANCES LIST
20/176
599 72 40-80