EWM1000plus EWM2000evo EWM3000new
2.7 LCD Version without selector and button ON/OFF switch
2.7.1
Access to diagnostics system
1. Reset the set programme and switch the appliance off.
2. Press the 10 and 11 buttons, simultaneously, then, holding them down, switch the appliance on with
ON/OFF button.
3. Hold the buttons down till DIAGNOSTIC MODE appears (about 5 seconds).
4. To exit the diagnostic system switch the appliance off, on and then off again.
2.7.2
Rapid reading of alarm codes
The last alarm code can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
Five minutes after the switching on, press and hold down the 10 and 11 buttons simultaneously for 2
seconds, the LCD display shows the last alarm codes (of the main board and display board). The
displaying of the alarms depends on the time in which the buttons are hold down.
During the time the alarm is displayed, the appliance continues to perform the cycle or, if it is in the
selection phase, it keeps in memory the options previously chosen.
2.7.3
Cancelling the last alarm
It is good practice to cancel the last alarm, after reading the alarm code to check whether the alarm re-
occurs during the diagnostics control after the reparation of the appliance
1. Select diagnostic mode and with button 4 go to tenth position (alarm reading)
2. Press simultaneously buttons 10 and 11.
3. Hold them down until the alarms are cancelled.