9 Maintenance
The operations described below shall only be performed
with the boiler and power supply off.
9.1 Sweeping
The boiler will only operate efficiently if the exchange surfaces
are kept clean.
Cleaning the flue gas circuit
- Switch off the boiler electrical power supply.
- Unhook the front panel.
- Open the cleaning door (top door) by unscrewing the 4 closing nuts
(17 mm spanner),
- Remove the baffle plates,
- Carefully sweep the flue ways with the brush supplied for that
purpose,
- Also sweep the baffle plates and the front panel,
- If possible, use a vacuum cleaner,
- Replace the baffle plates,
- Close the door.
20/09/2011 - 300016243-001-D
The boiler should be cleaned as soon as required and as the
chimney, at least once a year or more, depending upon applicable
regulations and specific needs.
Cleaning the combustion chamber
- Unscrew the 4 closing nuts and open the furnace door
- Brush out the inside of the furnace
- Use a vacuum cleaner to remove any soot which has accumulated
in the combustion chamber
- Close the door and replace the front panel.