Error Codes - NCI 6720 User Manual

Point-of-sale interface scales 6700 family
Hide thumbs Also See for 6720:
Table of Contents

Advertisement

RS-232 Interface
* Jmp1 and Jmp2 pins
are connected
internally on the scale
PCB connector.

Error Codes

24
The 9-pin version of the 6700 has DE type
female connector accessible at the rear of the
unit. The functional pinout of this connector is
compatible with a standard PC with a pass-
through cable.
DE-9 Female Scale
Pin Name Direction Pin Name Direction
1.
JMP 1
2.
TXD
3.
RXD
4.
JMP 1
5.
SG
6.
JMP 1
7.
JMP 2
8.
JMP 2
9.
NC
Any system errors detected by the scale will be
displayed as the letter E followed by a two-digit
error code. Press the TEST key to continue
operation. If a calibration error occurs, the only
way to clear it is by recalibrating the scale.
The error codes are broken down into two
hexadecimal numbers, with each bit defining a
single error condition. The error codes are
defined as follows:
Model 6700 Family User's Manual
DE-9 Male Host
-
1.
DCD
OUT
2.
RXD
IN
3.
TXD
-
4.
DTR
-
5.
GRD
-
6.
DSR
-
7.
RTS
-
8.
CTS
-
9.
IN
IN
OUT
OUT
-
IN
OUT
IN
RI
IN

Hide quick links: