NCI 7050 User Manual

Bulk sampling scale
Hide thumbs Also See for 7050:

Advertisement

Quick Links

Model 7050
Bulk Sampling Scale
User's Manual

Advertisement

Table of Contents
loading

Summary of Contents for NCI 7050

  • Page 1 Model 7050 Bulk Sampling Scale User’s Manual...
  • Page 2: United States

    UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents ..................i Specifications ..................1 Introduction ................... 3 Unpacking and Preparing the 7050 ............3 7050 Description ..................4 Front Panel Keys ................4 Hard Keys ................. 5 Softkeys ..................6 Weighing Operations ................7 Single Piece Weighing ..............
  • Page 4: Specifications

    Current Base, Center of Zero, Unit of Measure and Display Label. 240 x 64 dot matrix LCD display Display 5" x 1.33" displayable area 7050: Cold cathode fluorescent backlit (white on blue) Selectable, 0.1 to maximum readable updates Display rate Pounds, kilograms, ounces, pounds and...
  • Page 5 Harmonizer digital filtering Fully selectable to ignore noise and vibration Memory Capable of storing one record for recall including ID #, pieces, weight, pieces per lb., and piece weight. Power saving Scale has 2 power-saving timers; one controls backlight, and another has capability of shutting the scale off.
  • Page 6: Introduction

    Introduction This manual explains the operation of the 7050 bulk sampling scale. The 7050 is a computer- based counting scale specifically configured for bulk mail applications. This manual explains only the basic application which ships from the factory and also assumes all the functions of the scale are enabled.
  • Page 7: 7050 Description

    Com2 is used for Orion printer connection only. Front Panel Keys The keys on the front panel of the 7050 are of two types; hard keys and softkeys. Hard keys are labeled directly and softkey labels appear on...
  • Page 8: Hard Keys

    the display. Softkeys function differently at different times and their labels change as needed. Hard Keys Below are brief descriptions for each of the hard key functions: ESCAPE ESCAPE ESCAPE ESCAPE ESCAPE ESCAPE ESCAPE Press the ESCAPE ESCAPE ESCAPE key to back out of menus or cancel an entry and return to gross weight mode.
  • Page 9: Softkeys

    Left Arrow Left Arrow Left Arrow key to Right Left Arrow scroll between the two tiers of soft keys. The softkeys which appear in the 7050 BSS application are as follows: First Tier: First Tier: First Tier: First Tier: First Tier:...
  • Page 10: Weighing Operations

    Weighing Operations The basic unit Model 7050 will operate in the following manner: After system check, Area A will indicate a stable condition and center of zero, Area B will display 0.000 lb. Gross, Area C will display 0.000 lb.
  • Page 11: Single Piece Weighing

    Single Piece Weighing Place a single piece on the weight platter. Using the “UNITS” soft key, you can toggle between 0.001 lb. and 0.01 oz. The weight of the single piece will be displayed in Areas B and C. Gross Weighing Follow these steps to perform a gross weighing operation.
  • Page 12: Entering A Known Tare Weight

    4. Place the material to be weighed in the container. . . Net weight is displayed. 5. To remove the tare weight from memory, empty the scale platform and press the T T T T T ARE ARE key. . . Scale returns to gross weighing mode.
  • Page 13: Sampling In Dribble Mode

    scale uses this to determine the count of pieces placed on the scale. The piece weight is kept in memory until a new sample is taken. You can sample using the bulk or dribble modes. F F F F F actory default is dribble mode actory default is dribble mode actory default is dribble mode actory default is dribble mode...
  • Page 14: Sampling In Bulk Mode

    key in a new sample size larger than 10. Press the ENTER key, then count out the new sample amount onto the scale and press ENTER. . . The display shows Standby Standby Standby Standby..
  • Page 15: Counting While Using A Container

    Entering Numeric Values The 7050 will allow entry of numeric values for manual weight (Man. Wt), piece weight (lb/ PCWT), pieces per pound (PC/lb), or ID number (ID No.).
  • Page 16: Reverse Sampling

    Reverse Sampling You can determine the entire count of a container without emptying the container. This is called reverse sampling. If at this time, a loaded container with a predetermined tare value is placed on the weight platter, the tare value can be entered, by keying in the value on the 0-9 keyboard.
  • Page 17 Notes...
  • Page 18 1000 Armstrong Drive Fairmont, MN 56031 USA Telephone: 507-238-4461 Facsimile: 507-238-4195 E-mail: service @wt-nci.com www.wt-nci.com...