Alternate
Calibration Points
Table 1
Alternative
Calibration Points
Baud Rate and
Parity Options
Table 2
Baud Rate and
Parity Options
12
The NCI 6700 bench scales allow calibration
using less than full capacity weights. See Table 1
for alternative weights that can be used to
calibrate your scale for its designated capacity.
Capacity
9.995 lb
15 x .005 lb
7 x .002 kg
9.995 kg
30 x .01 lb
15 x .005 kg
60 x .02 lb
30 x .01 kg
99 x .05 lb
120 x .05 lb
60 x .02 kg
Display
12 E
24 E
48 E
96 E*
19.2 E
12 o
24 o
48 o
96 o
19.2 o
12 n
24 n
48 n
96 n
19.2 n
*Default Factory Settings
Model 6700 Family User's Manual
Alternative
Calibration Weights
10 lb
10, 15 lb
7 kg
10 kg
10, 20, 30 lb
10, 15 kg
10, 30, 60 lb
10, 20, 30 kg
10, 50, 100 lb
10, 50, 100 lb
10, 30, 60 kg
Baud
Parity
1200
Even
2400
Even
4800
Even
9600
Even
19.2K
Even
1200
Odd
2400
Odd
4800
Odd
9600
Odd
19.2K
Odd
1200
None
2400
None
4800
None
9600
None
19.2K
None