Clearances To Combustibles; Venting Components & Configuration - HearthStone DVI-Ht 8890 Owenrs Manual

Dvi-ht gas fired direct vent insert heater
Hide thumbs Also See for DVI-Ht 8890:
Table of Contents

Advertisement

OWNER'S MANUAL
CLEARANCES TO
COMBUSTIBLES
Due
to
high
surface
temperatures,
the
should be located away
from
furniture
draperies.
Clothing
other flammable material
should not be placed on or
near the heater.
Always
maintain
adequate
clearances around the air
openings in the façade and
allow
for
adequate
ventilation.
Minimum

clearances to combustibles

must
be
maintained
shown in Figure 2.
VENTING COMPONENTS &
CONFIGURATION
The DVI-Ht cannot be vented jointly with any other
solid fuel or gas appliance. The DVI-Ht must be vented
directly to the outside of the building using a proper
termination as listed in the next three pages. The venting
configuration is shown in Figures 4 & 5. If the vent-air
system is disassembled for any reason, reinstall per the
instructions provided in the Assembling The Unit section
of this manual on page 12.
Figure 2: Clearance To Combustibles (* Insulation is recommended)
unit
and
and
as
*INSULATION
8" - TO ALL SIDE WALLS
13" - WITH 1" TRIM
15" - WITH 7.5" MANTLE
HEARTHPAD REQUIRED 14" IN FRONT OF UNIT
TRIM OR
MANTLE DEPTH
(INCHES)
2
4
6
8
10
44-5/8
COMBUSTIBLE
MANTLE IN
42-5/8
THIS AREA
40-5/8
HEIGHT
38-5/8
ABOVE
HEARTH
36-5/8
34-5/8
(INCHES)
32-5/8
NOTE: IF THE OPTIONAL
30-5/8
THRESHOLD IS USED ADD 1.5"
TO THE MANTLE CLEARANCES.
28-5/8
26-5/8
Restrictor Disc
Your DVI-Ht has been supplied with a restrictor disc.
This disc will provide excellent restriction for vertical
vent runs exceeding 20 feet. If your vertical rise is less
than 20 feet, the use of the restrictor is not necessary.
Figure 3
Restrictor
E X H A U S T
IN T A K E
See Figure 3.
7
Model # 8890 DVI-Ht
12
14
16
18
20
22
COMBUSTIBLES CAN NOT EXTEND
BELOW THE TOP OF THE SURROUND,
NON-COMBUSTIBLES CAN.