WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids near this or any other gas
appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch electrical switches; do not use
the phone in your building.
• Immediately call your gas supplier from a
neighbors phone. Follow your gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
A qualified installer, service agency or gas supplier
must perform installation and service. In the
Commonwealth of Massachusetts, all installation
of gas lines and gas fitting shall only be done by a
licensed gas fitter or licensed plumber.
HearthStone Quality Home Heating Products, Inc.
317 Stafford Avenue,
Morrisville, Vermont 05661-8695
E-Mail: Inquiry@hearthstonestoves.com
GAS-FIRED
(8701)
READ THIS OWNER'S
MANUAL
Operate and maintain this gas heater
according to this instruction manual.
Read This Manual In Its Entirety.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions donné dans cette notice
pour réduire au minimum le risque d'incendie
ou pour éviter tout dommage matéeriel, toute
blessure ou la mort.
Ne pas entresposer ni utiliser d'essence ni d'autre
vaperurs ou liquides inflammables dans le
voisinage de cet apprareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le
batiment où vous vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifié installer, agence de service ou le
fournisseur de gaz.
6400-40450
03-23-07
Model #8701

Advertisement

Table of Contents
loading

Summary of Contents for HearthStone Tucson 8701

  • Page 1: Read This Owner'smanual

    Owner’s Manual & Installation Guide READ THIS OWNER’S MANUAL Tucson Operate and maintain this gas heater for the GAS-FIRED (8701) according to this instruction manual. DIRECT-VENT HEATER Read This Manual In Its Entirety. WARNING: If the information in these AVERTISSEMENT: Assurez-vous de bien instructions is not followed exactly, a fire or suivre les instructions donné...
  • Page 2: Service Record

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 INFORMATION SHEET Use this page to record all relevant information concerning the purchase, installation, and maintenance of your TUCSON Gas-Fired Direct-Vent heater. This information will facilitate servicing, purchase of replacement parts, and warranty claims (if necessary). Keep your original receipt in a safe place as proof of purchase.
  • Page 3: Introduction

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 thermostat with the On/Off/T’stat switch by NTRODUCTION setting it to “ON” or “OFF”. Congratulations on your purchase of the Tucson Model 8701, Gas-Fired Direct-Vent The Unit can also be equipped with an heater.
  • Page 4: Table Of Contents

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 Do not use this appliance if any part was ABLE OF ONTENTS under water. Immediately call a qualified READ THIS OWNER’S MANUAL..1 service technician to inspect the heater and to replace any part of the control system and gas ...........
  • Page 5 HearthStone Quality Home Heating Products Inc Tucson Model #8701 not cut or remove the grounding prong from the this manual. Due to high temperatures the plug. appliance should be located out of traffic and away from furniture, draperies, UST BE ENTED TO THE clothing flammable...
  • Page 6 HearthStone Quality Home Heating Products Inc Tucson Model #8701 Always wear gloves and safety goggles while handling the log set and ember materials. LECTRICAL AZARD When the optional blower kit is installed, the Tucson must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI.NFPA 70 in the U.S.
  • Page 7 HearthStone Quality Home Heating Products Inc Tucson Model #8701 OBILE NSTALLATIONS ERVICE AUTION This appliance may be installed in an shield, door, safety screen aftermarket, permanently located, component removed for servicing will be manufactured (mobile) home, where not replaced prior to operating. If you believe prohibited by local codes.
  • Page 8: Specifications

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 SPECIFICATIONS: Gas-Fired Direct-Vent Fireplace Heater ISTED Model: Tucson Direct-Vent Gas Fireplace Heater (8701) Testing Agency: Intertek Testing Services NA, Inc. (ITS) Tested to: ANSI Z21.88-2002, CSA 2.33-M02, CAN/CGA2.17-M91 Certified for Canada, CSA P.4.1 Approved for Mobile Home Installation (see page 7) Figure 1: Tucson Dimensions FUEL TYPE:...
  • Page 9: Owner ' S Information

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 overall efficiency of the unit as the heat ’ WNER NFORMATION from the pilot is wasted. When putting the The installation must conform with local unit back into service, follow the lighting codes or, in the absences of local codes, the instructions described on page 30.
  • Page 10: Unpack And Inspect For Damage

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 Manufactured Home Construction ACKING Safety Standard, Title 24 CFR, Part 3280 1-Tucson Gas-Fired Heater (U.S.) or Standard for Manufactured Home 4-Decorative Ceramic Logs Installation, ANSI/NCBCS A225.1 1-Bag Charcoal Embers Only Standard for Gas Equipped Recreational 1-Bag Charcoal Embers and “Rock Wool”...
  • Page 11 HearthStone Quality Home Heating Products Inc Tucson Model #8701 With the accessory box removed and set vent pipe’s minimum clearance, depending aside, undo the lag bolts that fasten the unit on whether the installation calls for vertical to the pallet. Take care not to mar or chip rise within the room or a rear exit, through- the enameled legs.
  • Page 12 HearthStone Quality Home Heating Products Inc Tucson Model #8701 Figure 4: Minimum Venting-Mantle Clearance To Combustibles Figure 6: Snorkel-Mantle Clearance To Combustibles Figure 5: Minimum Venting-Wall Clearance To Combustibles The corner clearance for the Tucson is 2”, to be measured from the edge of the top Figure 7: Snorkel-Wall Clearance To castings, to the adjacent wall.
  • Page 13 HearthStone Quality Home Heating Products Inc Tucson Model #8701 Acceptable Direct-Vent TERMINATION Cap locations. Figure 8 23037-1...
  • Page 14: Venting Information

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 ENTING NFORMATION ONNECTION Starter collar is installed by HearthStone. 1. The Tucson Direct Vent is approved for installation only with vent connecting components listed on this page and Simpson Dura-Vent Direct Vent AmeriVent Direct,...
  • Page 15 HearthStone Quality Home Heating Products Inc Tucson Model #8701 (Refer to Figure 11 for proper adjustment ESTRICTION LATE plate index location) ‘A’ in Figure 11 shows The restriction plate is used to control the the locating screw that determines the draft of the heater.
  • Page 16 HearthStone Quality Home Heating Products Inc Tucson Model #8701 Listed below are Simpson Dura-Vent, & ENTING OMPONENTS AmeriVent Direct, and Secure EXCELDirect ONFIGURATION Vent components acceptable for installation, The Tucson cannot be vented jointly with along with the minimum venting kit any other solid fuel or gas appliance.
  • Page 17 HearthStone Quality Home Heating Products Inc Tucson Model #8701 14" snorkel Centerlines shown are approximate. Please dry fit your venting and take a wall thimble wall thimble cover measurement. Pipe dimensions will vary 9"straight by manufacturer and supplier. 45 degree elbow See installation instructions on page 23.
  • Page 18 HearthStone Quality Home Heating Products Inc Tucson Model #8701 PPROVED ERTICAL ERMINATION ENTING ONFIGURATIONS (2) 45 LBOWS OR FFSETS (2) 90 IGURE LBOWS IGURE • 10' minimum system height (with or without offsets) • 35' maximum system height • 6' maximum offset (refer to Figure 14) •...
  • Page 19 HearthStone Quality Home Heating Products Inc Tucson Model #8701 PPROVED ENTING ONFIGURATION FOR ORIZONTAL ERMINATION (1) 90 LBOW • The termination must fall within the area outlined by the shaded area shown in the illustration below. • A minimum of 9" rise is required directly off the heater. •...
  • Page 20 HearthStone Quality Home Heating Products Inc Tucson Model #8701 “A” C PPROVED ONFIGURATION IREPLACE AND LASS HIMNEY NSTALLATIONS • The termination must fall within the demarcation line shown in illustration. Use the indicated restriction plate position. Restriction plate # 5950-922. The use of an existing chimney as an air intake is not listed under the ANSI Z21.88-1998-CSA 2.33-M98 test methods;...
  • Page 21 HearthStone Quality Home Heating Products Inc Tucson Model #8701 straps extend through interior wall NSTALLATION NSTRUCTIONS thimble. Before attaching the vent FOR THE TANDARD ORIZONTAL termination to the outside of the ERMINATION INIMUM house, run a bead of non-hardening #97-65001) ENTING mastic around its’...
  • Page 22: Electrical Connections

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 LECTRICAL ONNECTIONS NOTE: OPEN VALVE DOOR UNDER THE ASH LIP FOR ELECTRICAL AND GAS CONNECTIONS. central heating system, or a nearby drafty HERMOSTAT window. The ON/OFF/T’stat switch or wall mounted thermostat controls the Tucson. Placement of the thermostat on an inside recommend installation of the thermostat for wall rather than an outside wall is...
  • Page 23 HearthStone Quality Home Heating Products Inc Tucson Model #8701 IRING NSTRUCTIONS • CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. (Attention: Au moment de l’entretien des commandes, étiquetez tous les fils avant le débranchement.
  • Page 24: Gas Supply & Connections

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 NOTE: If an optional blower is to be installed now or in the future, make sure the gas line is installed as close to the floor as possible. Figure 20: Gas Control Valve &...
  • Page 25: Log Placement

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 pressure. We recommend a flexible line to log set is damaged or broken contact your avoid undue mechanical load on the valve dealer for replacement. The decorative and to ease thread alignment, but refer to ceramic log set will last a long time, local codes.
  • Page 26 HearthStone Quality Home Heating Products Inc Tucson Model #8701 3. Gently slide the Forked Log (1) onto 6. Gently place the Top Log (4) in the the Right post and the Rear post, indentation on the Cordwood Log (2) with the forked end toward the front and the pilot assembly, being sure to right of the firebox.
  • Page 27 HearthStone Quality Home Heating Products Inc Tucson Model #8701 23037-1...
  • Page 28: Lighting The Unit For

    HearthStone Quality Home Heating Products Inc Tucson Model #8701 by adhering to the following break-in EMOVAL OF procedure. CAUTION: The log set and charcoal embers REAK ROCEDURE retain heat and can be very hot! Allow 2 to 3 hours after pilot light is turned off before When lit the first time, the Tucson should be handling.
  • Page 29: Initial Adjustments

    HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent Clearances Combustibles, Venting ILOT IGHT ARNING Components & Configurations, Electrical The Tucson has a piezoelectric spark igniter Connections, Supply (the red push button located next to the gas Connections sections of this manual, the unit control valve behind the valve access door), is almost ready to be lit for the first time.
  • Page 30 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent To determine if the air shutter needs 4. Push in and turn gas control knob adjustment, it is necessary to view the flame clockwise to “OFF”. (If not previously pattern with the variable output control knob lit, the knob should be in this position.)
  • Page 31 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent 10. Shut the gas control valve access door. PPLIANCE 11. Plug in the fan accessory, if so equipped. 1. Set the thermostat to the “OFF” 12. If T’stat was selected, set thermostat to position or turn the ON/OFF/T- “ON”...
  • Page 32 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent ILOT DJUSTMENT URNER LAME PPEARANCE The pilot light is preset by the manufacturer Once the unit is lit, observe the flame and should not need adjustment. The pilot pattern and adjust as necessary.
  • Page 33: Routine Maintenance And Care

    HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent surface of the log set. Thoroughly vacuum OUTINE AINTENANCE the ports (holes) along the top of the pan burner, and the pilot assembly. The Tucson requires minimal routine With the decorative ceramic logs out of the maintenance and care.
  • Page 34 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent 6. Starting at one end, press the gasket into EPLACE THE RONT the channel. Ensure a good joint where ASKET AS EEDED the gasket ends meet before trimming Your Tucson uses 3/8”...
  • Page 35: Parts Lists

    HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent ARTS ISTS Part # Description Part # Description 1741-350 3-5/16” x 10-5/16”(84 x 262) Stone 7200-340 Burner Orifice (NG) #40 1741-351 7-1/2” x 6-1/2” (190.5 x 165) Stone 7200-353 Burner Orifice (LP) #53...
  • Page 36: Troubleshooting

    HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent TROUBLESHOOTING Symptom Possible Cause Corrective Action 1. Pilot will not A. Insufficient gas pressure, A. Using the piezo sparker, try to light the light. air in the pilot line, or dirty or pilot.
  • Page 37 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent TROUBLESHOOTING Symptom Possible Cause Corrective Action 3. Pilot burning, no A. Thermostat switch or A. Check thermostat/wiring for proper gas to main burner, wires defective. connections. Place jumper wire across valve knob in the terminals at thermostat.
  • Page 38 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent TROUBLESHOOTING Symptom Possible Cause Corrective Action 8. Floating flames, A. Potentially dangerous A. Check the appliance input rate and reduce lazy ill-defined, incomplete combustion due if necessary. The air intake/exhaust flow...
  • Page 39 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent ATING ABEL 8701- MODEL # 18001 SERIAL # MODEL NAME: TUCSON DIRECT VENT GAS FIREPLACE HEATER CERTIFIED FOR CANADA/HOMOLOGUE POUR LE CANADA LISTED: VENTED GAS FIREPLACE HEATER ALSO FOR MOBILE HOME INSTALLATION TESTED TO: ANSI Z21.88-2002 CSA 2.33-M02, CAN/CGA-2.17-M91...
  • Page 40: Hearthstone Gas-Fired Stove And Insert Limited Warranties

    HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent HEARTHSTONE GAS-FIRED STOVE AND INSERT LIMITED WARRANTIES These warranties give you specific legal rights. You may also have other rights that vary from State to State. HearthStone Quality Home Heating Products, Inc. (HearthStone) warrants to the original purchaser only (the “Original Purchaser”) the new gas-fired stove/insert manufactured by HearthStone and purchased by the Original...
  • Page 41 HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent EXCLUSIONS The warranties contained in this document do not cover, nor is HearthStone responsible for: 1. Damage resulting from installation or operation of the Stove in a manner contrary to the owner’s manual.
  • Page 42: Warranty Registration

    HearthStone Quality Home Heating Products, Inc. TUCSON 8701 Gas-Fired Direct-Vent REMEDY The remedy for any breach of the foregoing warranties will consist of repair or replacement, at HearthStone’s option, of any covered defect in the Stove. When the Original Purchaser contacts HearthStone or a Dealer,...

Table of Contents