Hunter-Pro 832/896/8144 Captain 8 S e c u r i t y S y s t e m s User Guide...
Page 2
HUNTER-PRO Series & CAPTAIN 8 User Guide Quick Reference Press for 2 seconds, enter Press the key for 2 seconds to... User code and press the key to... ON/OFF Arm to full mode, disarm Quickly arm to full mode Display the log BYPASS Temporarily bypass zones...
HUNTER-PRO Series & CAPTAIN 8 User Guide Table of Contents INTRODUCTION ....................5 Hunter-Pro & Captain 8 mutual features ..............5 Hunter-Pro Series unique features ................5 Captain 8 unique features ..................6 Safety & Security ....................6 Signs and conventions in this guide ................ 6 System codes ......................
Page 4
HUNTER-PRO Series & CAPTAIN 8 User Guide Adding RFID tag/keychain ................... 23 9.10 Deleting RFID Tag ....................24 9.11 The DURESS code ....................24 9.12 The Short code ....................24 9.13 The Door code ....................24 AUTOMATIC ARMING (KEY 9) ................25 10.1 By day and hour ....................
To assure optimal safety and security, you should perform a system test once a week. See section 1 3 for details. For any further questions, please contact your local PIMA distributor. Hunter-Pro & Captain 8 mutual features Hybrid systems with hardwired and wireless zones;...
HUNTER-PRO Series & CAPTAIN 8 User Guide Captain 8 unique features 8-16 zones; Up to 30 user codes & RFID tags; Various partitioning options: Up to 4 partitions; Up to 4 subsystems. Safety & Security Both the HUNTER-PRO Series &...
Each key menu is printed above it, e.g. “Time”, “Codes”. The LCD Keypad RXN-400, RXN-410 and RXN-410 RFID are PIMA‟s LCD keypads. They are designed for maximum simplicity and durability and present decorative design. The RXN-400 & RXN-410 are identical, except for their screen size: 410‟s is larger.
HUNTER-PRO Series & CAPTAIN 8 User Guide Figure 1. RXN-410 with the “Fast” display type ARMING & DISARMING THE SYSTEM (KEY #1) The system can be armed in one of 4 ways: Via the keypad; Automatically; Using Key fob, key switch and RFID tag/keychain; In Hunter-Pro only: by a remote control and via the phone.
HUNTER-PRO Series & CAPTAIN 8 User Guide When the Exit delay ends, the system becomes armed: the green ARMED LED stops to flash and stays on, the beeps stop, the message “System Armed” is briefly displayed and then the date and time are displayed. 2.1.1 Via the keypad Arming...
HUNTER-PRO Series & CAPTAIN 8 User Guide THE SYSTEM LOG (KEY #2) User Menu Show: Choose 1,2... All Events-0 User code Show: Show: Show: Faults Only-1 Zone Alarms-2 Arming/Dis.-3 The system logs alarms, arming & disarming, zone bypassing, faults, code changing and other actions, chronologically.
HUNTER-PRO Series & CAPTAIN 8 User Guide TEMPORARILY BYPASSING OPEN ZONES (KEY #3) Bypassing zones reduces the safety of your protected premises! It should be used carefully, only if there is no alternative and only for the shortest possible time. ...
HUNTER-PRO Series & CAPTAIN 8 User Guide To temporarily bypass a zone prior to arming: Zone Number: BYPASS ENTR Entr-Conf #-Rst User code zone number … approval message is displayed. Bypassed Zone Back door Zone name Zone number ...
HUNTER-PRO Series & CAPTAIN 8 User Guide To arm to the Home modes via the User menu: User code “Home 1” or for “Home 2”. The Exit delay for both Home modes can be cancelled by the Installer. DISPLAYING TYPES (KEY #5) Display Type: Display Type:...
HUNTER-PRO Series & CAPTAIN 8 User Guide The system indicators on the top line (between the time and the date) are: Indicator Description The system is communicating or testing the phone line The system is communicating over the Radio The RELAY output is active The SIREN output is active ...
HUNTER-PRO Series & CAPTAIN 8 User Guide The zones‟ status indicators are: Indicator Description Open zone The zone was violated when the system was armed, or is alarming now. Bypassed zone Zone Cut Zone Short Zone supervision Wireless zone low battery Anti-mask zone Disable zone displaying Display Type:...
HUNTER-PRO Series & CAPTAIN 8 User Guide 6.4.3 Soaked Zones Display Type: NEXT Display Soak Zn. NEXT User code to display other ENTR soaked zones - OR - repeatedly to display the zone‟s name, partitions and type. ...
HUNTER-PRO Series & CAPTAIN 8 User Guide Show partition names Display Type: BACK ENTR Show Part Name User code This is a toggle display type: when it is enabled, the names of the partition/s (see section ...
HUNTER-PRO Series & CAPTAIN 8 User Guide The dialer aborts the dialing attempts in the following cases: The system is disarmed. All numbers were dialed, each number twice (i.e., no call was answered). In HUNTER-PRO Series only, a remote control command is received. See section 1 4.1. ...
HUNTER-PRO Series & CAPTAIN 8 User Guide Press a number between 1 and 4 to call the corresponding programmed number. If a call is not received, check that the number is correct; if it is, call a service technician. ...
HUNTER-PRO Series & CAPTAIN 8 User Guide The “Master code” menu is visible only when entering the User menu with the Master code. Therefore, to change the code, you can only use the Master code. When entering the User menu with a User code and pressing “9”, the “User Codes” menu is displayed.
HUNTER-PRO Series & CAPTAIN 8 User Guide User settings User Codes User 1 (1) * CODES ENTR ENTER/NEXT/END User code ENTER/NEXT/END UTCMBKAORW User Settings ENTR NEXT ENTR ++++++-+--- user number ENTER/NEXT/END NEXT BACK ...
HUNTER-PRO Series & CAPTAIN 8 User Guide Disarming Time Frame User Codes User 1 (1) * CODES ENTR ENTER/NEXT/END User code ENTER/NEXT/END User 1 Disarm Window ENTR NEXT ENTR 00:00 To 23:59 ENTER/NEXT/END ...
HUNTER-PRO Series & CAPTAIN 8 User Guide Adding a key fob User Codes CODES NEXT ENTR User code ENTER/NEXT/END Add keyfob? User 1 (1) * ENTR NEXT ENTR ENTER/NEXT/END ENTER/NEXT/END user number Add keyfob? Device added! Activate device...
HUNTER-PRO Series & CAPTAIN 8 User Guide To force the user to enter its code when it disarms the system using an RFID tag/keychain, see the “User Settings” in section 9 .4. 9.10 Deleting RFID Tag User Codes CODES NEXT ENTR...
HUNTER-PRO Series & CAPTAIN 8 User Guide 10 AUTOMATIC ARMING (KEY 9) The Hunter-Pro Series & Captain 8 systems offer two ways to arm the system to full mode automatically: by day and hour, or by lack of activity. ...
HUNTER-PRO Series & CAPTAIN 8 User Guide When the auto-arming delay ends, the Exit delay starts, after which the system is armed. The Installer can enable auto-arming with open zones and faults. 11 THE CHIME FEATURE (KEY #) Zone Number: 1 ENTR-Conf #-Rst ...
HUNTER-PRO Series & CAPTAIN 8 User Guide 12.1.1 Examples Example A: private premises, single keypad Figure 2. Implementing partitions - Example A In this example, a single keypad controls all 3 partitions The users are all assigned to all 3 partitions and can therefore control them all. A user can control several partitions using a single code.
Page 28
HUNTER-PRO Series & CAPTAIN 8 User Guide Example C: variable options Figure 4. Implementing partitions - Example C In a 3 floors building, the first floor is defined as Partition #1, the second as Partition #2 and the third as Partition #3. There are 3 users and 3 keypads, with different authorization levels: User #2 is authorized to use all three keypads;...
HUNTER-PRO Series & CAPTAIN 8 User Guide Example E: business installation Figure 6. Common application for partitions The headquarters of a company is divided into 4 departments: each has its own keypad, employees, working hours, etc. The employees (i.e. users) can have access only to their department/partition, or to several. 12.1.2 Displaying armed partitions ...
HUNTER-PRO Series & CAPTAIN 8 User Guide The Visonic MCT-234 key fob has 4 push buttons. Pushing each button, or a combination of two, performs the next actions: Action Push button/s Arm to full mode Arm to “Home 1” mode Arm to “Home 2”...
HUNTER-PRO Series & CAPTAIN 8 User Guide Keystrokes Space Uppercase/Lowercase letters (toggle) Cancel/Return to previous screen without [END] saving [NEXT] Next character [BACK] Previous character [ENTR] Select/Save 12.4.1 Example The following demonstrates writing the word “KITCHEN”: Key Keystrokes Character NEXT NEXT NEXT...
HUNTER-PRO Series & CAPTAIN 8 User Guide 12.6 Resetting Smoke/Fire/Anti-mask detectors Smoke, Fire and Anti-mask detectors need to be reset if they are activated. They can be reset automatically or manually. To manually reset them: (press and hold the hash key for 2 seconds, until a confirmation tone is sounded). 12.7 Turning the keypad chime ON/OFF ENTR ...
HUNTER-PRO Series & CAPTAIN 8 User Guide Feature Captain 8 Hunter-Pro I/O-WN √ √ Wireless zones Key fobs Users RFiD tags VVR devices Events Log of which non-volatile 13 MANUAL SYSTEM TESTS (BACK KEY) User Menu Battery Test.. Battery Test.. BACK Finished OK! ...
HUNTER-PRO Series & CAPTAIN 8 User Guide 14.1 Basic mode To control the system remotely: 1. Call the phone number to which the system is connected (or pick a call from the system). 2. Wait for a confirmation tone: a long tone followed by 2 beeps. 3.
HUNTER-PRO Series & CAPTAIN 8 User Guide General System’s outputs Command Dial Output Dial Turn off the external * 00 Ext. SIREN siren and stop the dialer Int. SIREN Arm the system * 01 RELAY SMOKE Disarm the system ON/OFF Arm to “Home 1”...
HUNTER-PRO Series & CAPTAIN 8 User Guide 15 TROUBLESHOOTING Faults are indicated by the flashing red LED in the keypad, a description of the fault is displayed, the buzzer sounds beeps and the system logs it. In addition, the service technician can set the system to report it to the Central Monitoring Station, to send an alert by the telephone, to trigger an output and more.
Page 37
HUNTER-PRO Series & CAPTAIN 8 User Guide Fault Description and troubleshoot Detector voltage is faulty due to possible tampering. Call a service technician Detec Vol. Fault immediately! SMS Com. Failure SMS communication fault. Install SMS Unit No SMS unit is detected or the unit is faulty. Network Fault Network communication with the Central Monitoring Station is faulty.