A. Locating the Heater
The diagram (see Figure 1.2) shows space and clearance requirements for locating a heater within a room.
Rear Flue
1"MIN. (25mm)
A
A
B
Inches
42
22
Millimeters
1066
559
FIGURE 1.2
Heater Dimensions, Locations and Space Requirements
Minimum Clearances from the Heater to
Glass
Front
Floor
36 inches
0
(914 mm)
Clearance Requirements
The top, back, and sides of the heater are defined by standoffs.
The minimum clearance to a perpendicular wall extending past the face of the heater
is one inch (25 mm).
For 6000 Series Models, the back of the heater may be recessed 21-1/2 inches (546
mm) into combustible construction.
Minimum Clearances from the Flue Pipe to Combustible Materials
For Horizontal Sections
Top
Bottom
3 inches
1 inch
(75mm)
(25mm)
For minimum clearances, see the direct flue termination clearance diagrams on page 7.
B
E
D
C
3" (76.2mm)
C
D
E
38
53-3/4
76
965
1365
1930
Combustible Materials
Back of
Sides of
Heater
Heater
1/2 inch
1/2 inch
(13 mm)
(13 mm)
For Vertical
Sections
Sides
1 inch
(25mm)
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. C • 7/06
Top Flue
1" MIN. (25mm)
A
Inches
42
Millimeters
1066
Top of
Heater
Ceiling
3-1/2 inches
31 inches
(89 mm)
(787 mm)
Top
1 inch
2-1/2 inches
(25mm)
(63.7mm)
B
E
C
1/2" MIN. (12.5mm)
B
C
D
E
22
36
50-15/16
72
559
914
1294
1829
At Wall Firestops
Bottom
Sides
1/2 inch
1 inch
(13mm)
(25mm)
D
5