Ignition System Wiring - Heat & Glo 6000TRSI-AUC Installation And Operation Instructions Manual

Heat and glo fireplace
Table of Contents

Advertisement

E. IGNITION SYSTEM WIRING
• This gas fireplace is equipped with an electronic
ignition system which operates on a 6 volt system.
• This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory in-
stalled power cord for damage before using.
WARNING
Shock Risk
Replace damaged wire with type
O
105
C rated wire.
Wire must have high temperature
insulation.
PILOT
FIGURE 1.29
IGNITION MODULE
6VDC
BATTERY PORT
ON/OFF
SWITCH
GAS LINE
CONNECTED TO
BACK OF VALVE
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. C • 7/06
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause im-
proper and dangerous operation. Verify proper
operation after servicing.
FLAME SPARKER/
SENSOR
VALVE
REMOTE
CONTROL
ANT.
ON/OFF
WALL SWITCH
IGNITION
MODULE
(6V)
GROUND
NEUTRAL
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
VALVE
CAUTION
HOT
PLUG IN
19

Hide quick links: