BROWN
BLUE
FIGURE 1.30
Blower Fan
This heater has a factory installed blower fan,
electrical junction boxes, variable speed rheo-
stat control switch and temperature sensor
switch for the blower fan. These components
are located behind the lower door.
The factory installed power cord is attached
on the lower front right exterior side of the
heater. Figure 1.30 shows the blower fan,
switches, and blower fan wiring diagram.
See Figure 1.31 for wire connection detail.
20
NOTE: IF ANY OF THE ORIGI-
NAL WIRE AS SUPPLIED WITH
THE APPLIANCE MUST BE
REPLACED, IT MUST BE
REPLACED WITH TYPE 105
RATED WIRE.
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev.C • 7/06
C
BLACK
BLACK
BROWN
BLUE
TEMPERATURE
SENSOR SWITCH
GREEN/YELLOW
STRIPE
BLOWER
BLACK
(HOT) BROWN
BROWN
(NEUTRAL) BLUE
BLUE
FIGURE 1.31
VARIABLE
SPEED
CONTROL
BLACK
240VAC JUNCTION BOX
BLUE
BROWN
GREEN/YELLOW
BROWN
BLACK
BLUE