H. INSTALLER TESTING
The space heater must be tested and be operating
according to manufacturers specifications prior to the
installer leaving the site. Note: the tips of the flames
should never hit the top of the firebox after the unit
has warmed up. Please contact your dealer or a quali-
fied service person to replace injector or adjust valve.
Upon completing the gas line connection, a small
amount of air will be in the lines. When first lighting
the pilot light, it will take a few minutes for the lines to
purge themselves of this air. Once the purging is
complete, the pilot and burner will light and operate
as indicated in the Lighting Instructions.
Subsequent lightings of the appliance will not require
such purging.
Follow the Safety Information and Lighting Instruc-
tions pages of this manual to light the appliance.
To obtain proper operation, it is imperative that the
pilot and main burner flame characteristics are steady,
not lifting or floating. Typically, the top 3/8 inch
(9.5mm) of the thermocouple should be engulfed in
the pilot flame. (See Figure 1.34).
Pilot Assembly
FIGURE 1.34
Burner flame patterns are shown in Figure 1.35.
Follow TROUBLESHOOTING section for adjusting
the appliance to operate properly.
24
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev.C • 7/06
FIGURE 1.35

2.0 OPERATING INSTRUCTIONS

This appliance is a balanced flue heater and is de-
signed to operate with all combustion air being si-
phoned from the outside of the building and all ex-
haust gases expelled to the outside of the building.
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL.
The control system for this model employs an elec-
tronic pilot ignition. It consists of a 6V gas control
valve/variable regulator, an electronic module, a ther-
mocouple and a remote control. The controls are lo-
cated in the lower compartment behind the lower door,
and access is gained by lifting the door up. See Fig-
ure 1.
WARNING: DO NOT CONNECT 220-240 VAC TO
THE GAS CONTROL VALVE OR CONTROL WIR-
ING SYSTEM OF THIS UNIT.
When lit for the first time, the appliance will emit a
slight odor for an hour or two. This is due to paint and
lubricants used in the manufacturing process. Addi-
tionally, for the first few minutes after each lighting,
vapor may condense and fog the glass and the flames
may be blue. After a few minutes this moisture will
disappear and within 15-30 minutes the flames should
become yellow.
The heater may produce a noise, caused from metal
expansion and contraction as it heats up and cools
down. This noise is similar to one that a furnace or
heat duct may produce and does not affect the op-
eration or longevity of the heater.