Oven Temperature Sensor (
The RTD ( Resistive Thermal Device) has a
resistance of 1100 Ω at room temperature and
2650 Ω at clean temperature.

Right Cooling Fan

The right cooling fan is located in the right rear
corner of the control compartment and has an
approximate resistance value of 19 Ω.
Right Fan
Rear View
Right Fan
)
RTD
Sensor
– 20 –
Lower Cooling Fan (
The lower cooling fan is located between the
upper and lower ovens, and has an approximate
resistance value of 68 Ω.
The fan can only be removed from the back of the
oven.
Note: The right cooling fan and the lower cooling
fan of the Double Wall Oven are controlled by a
single relay.
)
Double Wall Oven Only