REMEHA P 520 Installation And Service Manual page 17

Fuel oil/gas boilers
Hide thumbs Also See for P 520:
Table of Contents

Advertisement

- Remove the baffle plates from the upper flue ways.
- Carefully sweep the flue ways with the brush supplied for that
purpose.
- Brush the baffle plates as well.
- If possible, use a vacuum cleaner.
- Unfasten the nuts up to the stop.
- Push in the handles of the sweeping covers.
- Remove the sweeping covers.
14/06/2012 - 300016859-001-01
- Remove the left and right-hand casing covers.
- Remove the top insulating material.
- Brush the vertical plates.
- Put back the sweeping covers, insulating material and casing
covers by reversing the procedure above.
Note: Chemical sweeping is recommended for such boilers.
- Put the baffle plates back in place. Interlock them with each other
while fitting them into the flue ways.
- Close the upper sweeping doors.
P 520